![Trinamic PD57-1060 Firmware Manual Download Page 32](http://html1.mh-extra.com/html/trinamic/pd57-1060/pd57-1060_firmware-manual_1163104032.webp)
PD57/60-1060 / TMCM-1060 TMCL™ Firmware Manual (V1.04 / 2011-AUG-29)
32
Copyright © 2011, TRINAMIC Motion Control GmbH & Co. KG
Example:
Set the absolute maximum current of motor to 200mA
Mnemonic:
SAP 6, 0, 200
Binary:
Byte Index
0
1
2
3
4
5
6
7
8
Function
Target-
address
Instruction
Number
Type
Motor/
Bank
Operand
Byte3
Operand
Byte2
Operand
Byte1
Operand
Byte0
Checksum
Value (hex)
$01
$05
$06
$00
$00
$00
$00
$c8
$d5