![Trinamic PD57-1060 Firmware Manual Download Page 55](http://html1.mh-extra.com/html/trinamic/pd57-1060/pd57-1060_firmware-manual_1163104055.webp)
PD57/60-1060 / TMCM-1060 TMCL™ Firmware Manual (V1.04 / 2011-AUG-29)
55
Copyright © 2011, TRINAMIC Motion Control GmbH & Co. KG
Number Global parameter
Description
18
general purpose variable #18
for use in TMCL™ applications
19
general purpose variable #19
for use in TMCL™ applications
20… 55
general purpose variables #20…
#55
for use in TMCL™ applications
Global parameters of bank 3, which can be used for RSGP:
The global parameter bank 3 is not required for the RSGP command.
Example:
Restore the maximum current of motor
Mnemonic:
RSGP 6, 0
Binary:
Byte Index
0
1
2
3
4
5
6
7
8
Function
Target-
address
Instruction
Number
Type
Motor/
Bank
Operand
Byte3
Operand
Byte2
Operand
Byte1
Operand
Byte0
Checksum
Value (hex)
$01
$0c
$2a
$02
$00
$00
$00
$00
$39