e-
ASK
Configuration — Doorbell
The following operations are dependent on system configuration.
Entering a 5-digit access code enables the keypad. After entering the
access code, one must press a 6th digit to unlock specific doors or
perform an operation according to the following listing.
Configuration A [SW 1 off / SW 2 off]:
•
Button (1): Unassigned
•
Button (2): Unlocks all entry and compartment doors
•
Button (3): Unassigned
•
Button (4): Toggles Aux 1 output
•
Button doorbell : Activates zone 6 unidirectional actuation
Configuration B [SW 1 off / SW 2 on]:
•
Button (1): Unlocks all entry door(s)
•
Button (2): Unlocks all entry and compartment doors
•
Button (3): Unassigned
•
Button (4): Toggles Aux 1 output
•
Button (doorbell): Activates zone 6 unidirectional actuation
Configuration C [SW 1 on / SW 2 off]:
•
Button (1): Unlocks all entry doors
•
Button (2): Unlocks all doors assigned to relay bank A
•
Button (3): Unlocks all doors assigned to relay bank B
•
Button (4): Unlocks all doors assigned to relay bank C
•
Button (doorbell): Activates zone 6 unidirectional actuation
Configuration D [SW 1 on / SW 2 on]:
Configuration D is standard for doorbell.
•
Button (1): Unlocks all entry doors
•
Button (2): Unlocks all entry and compartment doors
•
Button (3): Unlocks all compartment doors (banks C-D)
•
Button (4): Unlocks all compartment doors (banks A-B)
•
Button (doorbell): Activates zone 6 unidirectional actuation
Note:
•
See the table on page 9 for S2 DIP switch assignments.
•
Configuration D is the default.
6
Summary of Contents for 22272-03