background image

Teaching Keypad New Authority / Access 
Codes  

When you assign a new authority code, you delete the existing 
authority code and all access codes. 
 

Note:

 The authority code you assign following these instructions also 

becomes an access code saved to the (1 / 2) or (1) button. 
 

1.  Cycle (short then open) the S1 pins of the I/O module learn 

connector (Appendix B, page IV). There will be three-second 
beep. 

2.  Enter a new five-digit code—this will be your access and 

authority code. 

3.  Enter the new code again. 
4.  The existing code will only be erased if a new code is 

assigned. 

5.  The code is stored in position one. 

 

Important: 

Authority and access codes should not be the same. If 

someone figures out an access code and discovers it to be an 
authority code as well, they can then create their own access code 
and gain entrance to your vehicle. 
 
Once resetting the keypad, your next step should be to create a new 
access code and store it in position one so as to ensure the access 
code is no longer the same as the authority code. 
 

Notes: 

• 

The authority code is to be controlled by individuals (owners 
of vehicle, fleet manager, etc.) who manage the distribution of 
access codes to vehicle users.  

• 

The authority code should be changed when the vehicle is 
sold.  

• 

The authority code does not enable secure functions (lock/
unlock doors, etc.)—it is only used to assign access codes. 

 
The following area can be used to document the authority code: 

Digit 1 

Digit 2 

Digit 3 

Digit 4 

Digit 5 

 

 

 

 

 

Authority Code    

14 

Summary of Contents for 22272-03

Page 1: ...e ASK electronic Access Security Keyless entry Multiplex System Multiplex System Installation Instructions UM15 22272 03...

Page 2: ...ration D SW 1 on SW 2 on 5 e ASK Configuration Doorbell 6 Configuration A SW 1 off SW 2 off 6 Configuration B SW 1 off SW 2 on 6 Configuration C SW 1 on SW 2 off 6 Configuration D SW 1 on SW 2 on Addi...

Page 3: ...king and Unlocking 12 Auxiliary 1 Output Activation 12 Teaching Additional Transmitter FOBs 13 Teaching Keypad New Authority Access Codes 14 Assign New Access Codes 15 Troubleshooting 16 Appendix A Mo...

Page 4: ...mponents e FOB keyless entry radio frequency RF FOB transmitter and receiver e PAD keypad user interface or e GRAB keypad integrated grab handle Clean acrylic rod with mild soap and water only e ASK I...

Page 5: ...ssignment include interior exterior lighting awning extension retraction gas cap hood etc button Lock button Cargo e FOB Operation and Features Button Function Entry Lock Locks entry door and arms sec...

Page 6: ...doorbell e PAD Operation and Features The e PAD is shipped with default authority and access codes Unless the OEM or dealer has changed default codes the authority and access codes are as follows Acc...

Page 7: ...tes The authority code does not allow for secure operations It is only used to assign access codes see page 15 for information on setting access codes If an unassigned button or no button is pressed w...

Page 8: ...ntry and compartment doors Button 5 6 Unassigned Button 7 8 Toggles Aux 1 output Button 9 0 Activates zone 6 unidirectional actuation Configuration C SW 1 on SW 2 off Button 1 2 Unlocks all entry door...

Page 9: ...ent doors Button 3 Unassigned Button 4 Toggles Aux 1 output Button doorbell Activates zone 6 unidirectional actuation Configuration C SW 1 on SW 2 off Button 1 Unlocks all entry doors Button 2 Unlocks...

Page 10: ...s disabled e GRAB Handle Lighting The grab handle is lit continuously The e PAD is lit with a button press and while training new access and authority codes DIP Switch Settings for Keypad Configuratio...

Page 11: ...ompartment doors banks A B Pin 5 Locks entry door s Pin 6 Unlocks entry door s Trim Pot Variable Resistors These trim pots provide adjustable settings for timed outputs Clock wise rotation increases a...

Page 12: ...rd mode or cargo mode for the FOB transmitter Switch 4 ON cargo mode The top and bottom center buttons lock and unlock entry doors The left and right middle buttons lock and unlock compartment doors S...

Page 13: ...and the horn honks once with a lock command On unlock the headlights flash twice and the horn honks twice Cargo mode There is no unlock confirmation The headlights flash once and the horn honks once...

Page 14: ...mode both the entry door and compartment doors must be locked within 10 seconds to set the alarm The alarm is activated when any entry door or compartment door is opened or by grounding the extra secu...

Page 15: ...age 8 Starting the engine deactivates the light Automatic Locking and Unlocking When S2 DIP switch 3 is ON the auto locking feature is activated All doors are locked after the engine has been running...

Page 16: ...ill flash Up to 4 transmitters may be programmed at one time 4 Confirm that FOB transmitters lock unlock system Notes If you place the system in learn mode and teach nothing the system will exit in 10...

Page 17: ...should not be the same If someone figures out an access code and discovers it to be an authority code as well they can then create their own access code and gain entrance to your vehicle Once resettin...

Page 18: ...ivity you are defining 1 of 5 4 access numbers A subsequent code will be assigned to this access The keypad will provide a confirmation beep after this single button press 4 Enter in your new 5 digit...

Page 19: ...icular e FOB function does not work Check wire connection of affected function at RF module wiring harness and I O module Zone 6 activated inadvertently Verify that Zone 6 is not connected to the carg...

Page 20: ...odule Lights and panic mode do not turn off with ignition start Verify that connector J11 pins 7 8 and 9 are wired properly Output relay latches on or off Verify that power to relay comes from connect...

Page 21: ...iple locations to optimize reception The antennae must be left fully extended and exposed Minimize shielding from metal enclosures Top surface of the I O module has features that can be self tapped wi...

Page 22: ...Table 1 RF Receiver Assignments Table 2 Ignition Connections BLACK SYSTEM GROUND 1 2 3 BLUE CARGO LOCK OUTPUT 4 ORANGE ENTRY LOCK OUTPUT 5 RED 12V POWER 6 7 8 PURPLE CARGO UNLOCK OUTPUT 9 BROWN ENTRY...

Page 23: ...nidirectional Actuation Output E G Door Opening Battery Disconnect Doorbell J10 CONNECTOR Lock Unlock Bank D J8 CONNECTOR Lock Unlock Bank C J7 CONNECTOR Lock Unlock Bank B J5 CONNECTOR Lock Unlock Ba...

Page 24: ...ning PIN 7 Key Inserted PIN 6 Cargo Lock From RF Receiver PIN 5 Cargo Unlock from RF Receiver PIN 4 Unlock from RF Receiver PIN 3 Lock from RF Receiver PIN 2 12 VDC to RF Receiver PIN 1 Ground to RF R...

Page 25: ...Power Source PIN 3 GND PIN 2 GND PIN 1 12 V F2 RED 10 amp fuse protects Trinet Communications Power And Communication to the keypad F3 BLUE 15 amp fuse protects the power actuator outputs of the I O...

Page 26: ...ring Auxiliary outputs provide relay driver ground signal Diagram illustrates typical relay connectivity As shown 12 V pin should be used to power coil of relays Switch inputs are activated when sunk...

Page 27: ...ee from workmanship defects and will remedy issues per TriMark s warranty policy Remote transmitter FOBs batteries and other equipment subject to normal wear and deterioration may need to be replaced...

Page 28: ...UM15 22272 03 11 06 1...

Reviews: