Device Setup
Select the
Device Setup
link to adjust the following settings of the 8310 RSA:
• Current Channel Plan
– Select the down arrow
to the right of this field
to select the current
channel plan.
• Channel Plan Setup
– Select this button to
configure the system
channel plan. See
Channel Plan Setup
later in this section for
more information.
• Link Frequency
– Enter the link frequency into this field. The 8310 RSA has a minimum
link frequency of 0050.00 MHz and a maximum of 1000.00 MHz.
• TX Attenuation Level
– Enter the TX Attenuation Level into this field. The 8310 RSA
has a minimum attenuation level of 00.0 dB and a maximum of 31.5 dB.
• RX Level & Tap Value
– Enter the TX Level & Tap Value into their corresponding
fields. The 8310 RSA has a RX level range of 0 to 60 dBmV and a tap value range of
0 to 60 dB. The minimum tap level must be within 15 dB of the current RX level or the
instrument will automatically adjust the value to bring the tap value within the proper
range.
• Device Name
– Enter the name of the device into this field. The device name is limited
to 20 characters.
• Network Settings
– Choose between Static or DHCP network settings and enter the
corresponding IP Address, Subnet, Gateway, and DNS settings in the corresponding
fields. See Network Settings later
in this section for more information.
• Username & Password
– Enter the Username and Password into their corresponding
fields.
When finished updating or viewing the settings, reboot the
8310 RSA before closing your browser.