                Warnings related to the danger due to the presence  
              of electric voltage 

The safety instructions and mandatory directives listed below must be observed: 

 

Installation and maintenance must only be carried out by qualified personnel, 

in compliance with local directives; 

 

Keep children away when installing the photovoltaic system and photovoltaic 

modules; 

 

Danger of death due to electrical discharges and arc flashes; 

 

Contact  with  live  electrical  parts  of  the  PV  module,  such  as  terminals  and 

connectors, can cause burns, sparks and lethal electrical shocks; 

 

Comply  with  the  specific  safety  instructions  regarding  the  use  of  direct 

current  and  photovoltaic  systems.  When  exposed  to  sunlight,  photovoltaic 
modules produce direct current in hazardous amounts even in a single module. 
Photovoltaic modules are protected only with a DC switch; 

 

Never disconnect under load. Arc loads may occur that cannot be deleted; 

 

Do not touch the junction box, cable terminations and connecting plugs with 

bare  hands  during  installation  or  in  direct  sunlight,  whether  the  PV  module  is 
connected or not; 

 

Do not insert any component into the sockets or plugs; 

 

Do  not  perform  any  work  if  the  weather  is  wet,  in  order  to  avoid  electric 

shocks.  Do  not  use  wet  tools.  Do  not  work  on  the  wet  terminals  of  the 
photovoltaic module; 

 

Use  insulated  tools  and  rubber  gloves  suitable  for  working  on  electrical 

equipment; 

 

Always make sure that the photovoltaic module has been correctly fixed. 

Summary of Contents for TRIxxxBC-xB Series

Page 1: ...nergia S r l Strada Pavesa 13 A Bondeno di Gonzaga MN 46023 Italy VAT No 02470010204 www trienergia it info trienergia it 39 0 376 595052 1 Installation use and maintenance manual of the TRIxxxBC xB modules ...

Page 2: ...uctions can result in injury and property damage This manual is intended for qualified personnel and specialized technicians only The TRIxxxBC xB photovoltaic modules are photovoltaic panels used to transform solar irradiation into electricity Photovoltaic modules are designed to be used in photovoltaic systems Any other application is to be considered non conforming Disclaimer Trienergia assumes ...

Page 3: ...s Comply with the specific safety instructions regarding the use of direct current and photovoltaic systems When exposed to sunlight photovoltaic modules produce direct current in hazardous amounts even in a single module Photovoltaic modules are protected only with a DC switch Never disconnect under load Arc loads may occur that cannot be deleted Do not touch the junction box cable terminations a...

Page 4: ...y the necessary fall prevention measures during work at height Follow the applicable directives and recommendations of the work safety agencies or relevant organizations Do not work under rain snow or wind If you work at height pay attention to falling objects Handle damaged or broken photovoltaic modules with care using appropriate safety devices Do not touch the glass surface and the rear side o...

Page 5: ... under certain conditions Put the photovoltaic modules in environments where the operating temperature is within the range between 40 C and 90 C This condition is very important in order to ensure sufficient ventilation behind the photovoltaic modules in case of installation in environments particularly hot Do not use the photovoltaic modules in environments where they could come into contact with...

Page 6: ...ge or scratch the back of the photovoltaic module Do not hit any component of the photovoltaic module Do not lift the photovoltaic module by gripping the junction box or cables Do not pull twist or scratch the cables Do not disassemble the photovoltaic module and do not make unauthorized modifications Do not remove any labels Do not drill holes through the frame or the glass because it would compr...

Page 7: ...les according to the procedures described below The photovoltaic modules can be fixed to the mounting system using the appropriate clamps The TRIxxxBC xB photovoltaic modules can be mounted at any angle Choose the orientation of the modules to ensure maximum exposure to the sun The ideal exposure is towards the south in the northern hemisphere and towards the north in the southern hemisphere In Ce...

Page 8: ...mps for each photovoltaic module If several modules are installed one after the other use the intermediate clamps between modules Fix the appropriate clamps for photovoltaic modules following the measurements A and B specified in the chart below The following figure which represents the fixing clamp is for demonstration purposes only Therefore other types of clamps can also be used but they shall ...

Page 9: ...g points on the photovoltaic module as shown in the following images In case of installation of several photovoltaic modules next to each other leave a space between modules Never fit modules attached one to another as this may cause damage due to size changes caused by temperature The minimum recommended distance between the modules is 5mm 60 cell modules ...

Page 10: ...Gonzaga MN 46023 Italy VAT No 02470010204 www trienergia it info trienergia it 39 0 376 595052 10 Trienergia System 42 cell module in horizontal position with 21 cell modules Trienergia System 42 cell module in vertical position with 21 cell modules ...

Page 11: ... and quickly higher voltages make cross sections of smaller cables possible the higher voltages result in smaller currents and therefore lower power losses Parallel connection PV modules can be connected in parallel to achieve a higher output current Each string or photovoltaic module in series shall be fused before being combined with other strings For this purpose the TRIxxxBC xB modules are equ...

Page 12: ...r on the glass Be careful not to break or damage the grounding wire during routine maintenance of the photovoltaic module It is recommended to perform the following maintenance and inspection procedures regularly Cleaning of glass surfaces Snow removal if necessary Visual inspection of the fixing system Visual inspection of photovoltaic modules Visual inspection of electrical connections Performan...

Reviews: