              Warnings  related  to  the  installation  of  the  
              photovoltaic modules 

The safety instructions and mandatory directives listed below must be observed: 

 

Assembly and installation must only be carried out by qualified personnel, in 

compliance with local directives; 

 

Handle the photovoltaic modules with particular care; 

 

Do not use damaged photovoltaic modules; 

 

Pay  particular  attention  when  transporting  the  photovoltaic  module.  Be 

careful not to drop the module and avoid excessive loads. The solar cells in the 
module are very thin and naturally fragile; 

 

Do not 

step on the photovoltaic module

 and prevent any object from falling 

over it; 

 

Do not damage or scratch the back of the photovoltaic module; 

 

Do not hit any component of the photovoltaic module; 

 

Do not lift the photovoltaic module by gripping the junction box or cables. Do 

not pull, twist or scratch the cables; 

 

Do not disassemble the photovoltaic module and do not make unauthorized 

modifications. Do not remove any labels. Do not drill holes through the frame or 
the glass because it would compromise the stability of the frame or the glass; 

 

Do  not  cover  the  water  drain  holes  in  the  module  frame.  Damages  due  to 

freezing may occur if the frame is filled with water; 

 

Make sure that the insulating coating of the frame is not scratched, in order 

to avoid corrosion phenomena that may compromise the stability of the frame; 

 

Make sure that the connectors are properly tightened and check the wiring 

operation; 

 

Only  use  devices,  connectors,  cables  and  mounting  systems  suitable  for 

photovoltaic systems: 

 

After  installation,  check  the  correct  operation  of  the  photovoltaic  module 

and system. 

 

 

 

 

 

 

Summary of Contents for TRIxxxBC-xB Series

Page 1: ...nergia S r l Strada Pavesa 13 A Bondeno di Gonzaga MN 46023 Italy VAT No 02470010204 www trienergia it info trienergia it 39 0 376 595052 1 Installation use and maintenance manual of the TRIxxxBC xB modules ...

Page 2: ...uctions can result in injury and property damage This manual is intended for qualified personnel and specialized technicians only The TRIxxxBC xB photovoltaic modules are photovoltaic panels used to transform solar irradiation into electricity Photovoltaic modules are designed to be used in photovoltaic systems Any other application is to be considered non conforming Disclaimer Trienergia assumes ...

Page 3: ...s Comply with the specific safety instructions regarding the use of direct current and photovoltaic systems When exposed to sunlight photovoltaic modules produce direct current in hazardous amounts even in a single module Photovoltaic modules are protected only with a DC switch Never disconnect under load Arc loads may occur that cannot be deleted Do not touch the junction box cable terminations a...

Page 4: ...y the necessary fall prevention measures during work at height Follow the applicable directives and recommendations of the work safety agencies or relevant organizations Do not work under rain snow or wind If you work at height pay attention to falling objects Handle damaged or broken photovoltaic modules with care using appropriate safety devices Do not touch the glass surface and the rear side o...

Page 5: ... under certain conditions Put the photovoltaic modules in environments where the operating temperature is within the range between 40 C and 90 C This condition is very important in order to ensure sufficient ventilation behind the photovoltaic modules in case of installation in environments particularly hot Do not use the photovoltaic modules in environments where they could come into contact with...

Page 6: ...ge or scratch the back of the photovoltaic module Do not hit any component of the photovoltaic module Do not lift the photovoltaic module by gripping the junction box or cables Do not pull twist or scratch the cables Do not disassemble the photovoltaic module and do not make unauthorized modifications Do not remove any labels Do not drill holes through the frame or the glass because it would compr...

Page 7: ...les according to the procedures described below The photovoltaic modules can be fixed to the mounting system using the appropriate clamps The TRIxxxBC xB photovoltaic modules can be mounted at any angle Choose the orientation of the modules to ensure maximum exposure to the sun The ideal exposure is towards the south in the northern hemisphere and towards the north in the southern hemisphere In Ce...

Page 8: ...mps for each photovoltaic module If several modules are installed one after the other use the intermediate clamps between modules Fix the appropriate clamps for photovoltaic modules following the measurements A and B specified in the chart below The following figure which represents the fixing clamp is for demonstration purposes only Therefore other types of clamps can also be used but they shall ...

Page 9: ...g points on the photovoltaic module as shown in the following images In case of installation of several photovoltaic modules next to each other leave a space between modules Never fit modules attached one to another as this may cause damage due to size changes caused by temperature The minimum recommended distance between the modules is 5mm 60 cell modules ...

Page 10: ...Gonzaga MN 46023 Italy VAT No 02470010204 www trienergia it info trienergia it 39 0 376 595052 10 Trienergia System 42 cell module in horizontal position with 21 cell modules Trienergia System 42 cell module in vertical position with 21 cell modules ...

Page 11: ... and quickly higher voltages make cross sections of smaller cables possible the higher voltages result in smaller currents and therefore lower power losses Parallel connection PV modules can be connected in parallel to achieve a higher output current Each string or photovoltaic module in series shall be fused before being combined with other strings For this purpose the TRIxxxBC xB modules are equ...

Page 12: ...r on the glass Be careful not to break or damage the grounding wire during routine maintenance of the photovoltaic module It is recommended to perform the following maintenance and inspection procedures regularly Cleaning of glass surfaces Snow removal if necessary Visual inspection of the fixing system Visual inspection of photovoltaic modules Visual inspection of electrical connections Performan...

Reviews: