Installation
Terminal
Description
1
Positive terminal for a passive
4…20 mA pressure sensor
2
Negative terminal for a passive
4…20 mA pressure sensor
Connect the shield of the cables to protective ground (terminal 52).
WARNING!
The analog input is not short-circuit proof. Load currents above 35 mA (permanent load) or above 50 mA (short-
time load) can cause damages.
3.3.
Ex Installation
WARNING!
In hazardous locations all installations must only be carried out by qualified personnel!
Switch off all power supplies before installing or uninstalling the TRICOR Coriolis Mass Flow Meter in hazardous
locations!
Never connect a remote meter TCM to anything else than the specified electronics TCE 8***!
It is absolutely needed to read and to observe the
“Installation guide for hazardous locations”!