![Triax MCT 080 User Manual Download Page 88](http://html1.mh-extra.com/html/triax/mct-080/mct-080_user-manual_1160847088.webp)
FIELD METERS MCT 080 / 081 / 082 / 085 USER MANUAL
p.
87
You can choose:
mono : only one scan is made
0mn : the total scan starts again as soon as it is finished
1mn : the scan starts every minute
10mn : the measurement scan starts every 10 minutes
1h : the scan starts every hour
8h : the scan starts every 8 hours
24h : the scan starts every 24 hours
15.3 USB recording
You can save these measures on an USB stick :
Press
opens a CSV file is a stick is detected.
The save starts after browsing of all setups.
This is when the date and time are recorded.
The previous « Mode » key allows you to select the duration between two records of the list.
BERi
,
BERo
et
PER
are generic terms (frequently used)
BERi
= BER in = inner BER
first BER treated by the demodulator (BER channel, CBER, LDPC)
BERo
= BER out = outer BER
last BER treated by the demodulator (BER Viterbi, VBER, BCH)
PER
= packet error rate
non-proofread packet, lost packet, wrong packet (UNC, PER)
Important:
A bargraph under the Measurement map allows you to track the evolution of the scan.
The background color of this bargraph shows you that a complete scan has been made
(for a save, for example):
-
red
: the measurement map has not been totally scanned yet
-
green
: the measurement map has been totally scanned
In case of mixed measurement map (terrsatellite
), the satellite remote power
supply has priority (the terrestrial remote power supply is ignored).