FIELD METERS MCT 080 / 081 / 082 / 085 USER MANUAL
p.
82
Switch line
Uncommitted line
Satellite
Position
Commande DiSEqC
Position
Commande DiSEqC
1
Pos A
Option A + Position A
Pos 1
Input 1
2
Pos B
Option A + Position B
Pos 1
Input 1
3
Pos C
Option B + Position A
Pos 1
Input 1
4
Pos D
Option B + Position B
Pos 1
Input 1
5
Pos A
Option A + Position A
Pos 2
Input 2
6
Pos B
Option A + Position B
Pos 2
Input 2
7
Pos C
Option B + Position A
Pos 2
Input 2
8
Pos D
Option B + Position B
Pos 2
Input 2
9
Pos A
Option A + Position A
Pos 3
Input 3
10
Pos B
Option A + Position B
Pos 3
Input 3
11
Pos C
Option B + Position A
Pos 3
Input 3
12
Pos D
Option B + Position B
Pos 3
Input 3
13
Pos A
Option A + Position A
Pos 4
Input 4
14
Pos B
Option A + Position B
Pos 4
Input 4
15
Pos C
Option B + Position A
Pos 4
Input 4
16
Pos D
Option B + Position B
Pos 4
Input 4
14.2.3 Positioner
The appliance sends a DiSEqC command that triggers the rotation of a motorized satellite dish.
In this example, the p
osition is 9 (1 to 127 pre-loaded positions in the positioner)
If the positioner is on No, it is deactivated