14
N-Platform Hardware Installation and Safety Guide
flow of cooling air through the chassis. To prevent electric shock, do not open the enclosure
of the product.
Warning!
To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord.
Warning!
Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries
according to the instructions.
Warning!
When connecting equipment to IT power distributions, Phase to phase voltage must not
exceed 240 V. Always use the power adaptor and power cord shipped with the product to the
correct voltage.
Warning!
The ports on the front of the product are Safety Extra-Low Voltage (SELV) circuits. SELV
circuits should only be connected to other SELV circuits.
Warning!
This product might have more than one power supply source. All power sources must be
removed to de-energize the unit.
Warning!
Never touch uninsulated telephone wires or terminals unless the telephone line has been
disconnected at the network interface.
Warning!
Do not expose the product to strong magnets or magnetic fields.
Warning!
Keep all liquids and dust away from the product.
Warning!
All optical interfaces and sources connected to this product and its modules must only use
Class 1 lasers. Using any other Laser Class source can create hazardous conditions to the user.
Warning!
This product can contain Class 1 lasers. Do not stare into the laser beam or view it directly
with optical instruments. Install covers for the laser connectors when they are not in use.
Warning!
Use caution when touching exposed metallic surfaces, which can become hot during normal
operation.
Warning!
The cards and modules can get hot during operation. When removing a card or module, hold
it by the faceplate and bottom edge. Allow the card or module to cool before touching any
other part of it or before placing it in an antistatic bag.
Warning!
The product uses double pole/neutral fusing. Use caution when servicing this product.
Warning!
The user must install only Optical Transceiver Modules that comply with the appropriate
standard and/or regulation - UL 60950-1, FDA/CDRH 21 CFR 1040 Class 1, or (IEC/
CENELEC) EN 60825 Class 1.
Rack and clearance requirements
Tipping Point recommends that you mount the product in a standard 19-or 23-inch rack.