PLUMBING CONNECTIONS

All water connection operations must be 

performed after making sure that the minipool's 

water supply valve is CLOSED. 

The connection must be made by an experienced, 

qualified plumber.

It is recommended to use ONLY tap water. If this 

is not possible refer to the "more information" 

section to the side.

The plumbing connection must be:

•  Dedicated exclusively to the minipool (it is not possible 

to connect other equipment to the same connection).

•  Made with hoses and connectors that are new and 

never used.

CHARACTERISTICS OF THE WATER SUPPLY

The optimal values   for the water supply are as follows:

•  Hardness between 7ºf and 14ºF (fresh water) - 200 to 

400 mg/l (ppm).

•  Total alkalinity (TA) between 80 and 125 mg/l (8-12.5°F).

•  pH between 7.4 and 7.8.

•  minimum inlet pressure: 150,000 Pa (1.5 bar)

•  minimum inlet pressure: 300,000 Pa (3 bar)

•  Water suitable for human consumption.

Make sure that during the pre-installation all the 

characteristics of the water supply have been met (see 

"Pre-Installation Sheet" on p. 9).

More information

WATER HARDNESS

Water hardness (TH) is determined by the total content 

of calcium and magnesium present in the water, coming 

from their soluble salts.

Water classification:

........up to 7ºf         

=  

Very soft water

From 7ºf to 14ºf     

=  

Soft water

From 14ºf to 22ºf    

=  

Slightly hard water

From 22ºf to 32ºf    

=  

Fairly hard water

From 32ºf to 54ºf    

=  

Hard water

........more than 54ºf  

=  

Very hard water

(1°f = 10 mg calcium carbonate per litre of water)

WATER ALKALINITY

Alkalinity (CAT) represents the concentration of 

bicarbonate ions present in the water. It is expressed 

as mg/L of calcium carbonate or in French degrees (°F). 

Ideal values   of alkalinity range between 80 mg/L and 

125 mg/L (8°F-12.5°F). Values   outside of this range 

can more easily cause variations of the pH. Instead, 

alkalinity within the range noted makes it possible 

to "buffer" the pH value, resulting in fewer abrupt 

variations.

WATER PH

What is pH?

The pH is a chemical parameter that gives an idea of   

the acidity or basicity of the water. It can assume values   

between 0 and 14. By definition water is considered 

neutral if its pH is equal to 7. It is acidic if the pH is lower 

than 7 and basic if the pH is greater than 7. Disinfectants 

have an ideal pH at which they are most effective. In 

the case of heated water treated with bromine products 

it is recommended to keep the pH value in the range 

from 7.4 to 7.8 using chemical correctors as needed 

if the pH is higher or lower to bring the the pH value 

back to the recommended interval. 

acqua acida

acqua alcalina

pH acido

pH neutro

pH basico

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14

More information

TAP WATER AND WELL WATER

To ensure maximum hygiene and durability of the 

minipool it is essential to pay close attention to the 

quality  of  the  water  that  will  be  used  to  fill  it.  It  is 

important that the water used be drinkable. It is always 

advisable not to use well water because it may be very 

hard, rich in metals like iron and manganese, and have 

bacterial loads. Tap water is recommended. In the case 

of very hard or ferrous water it is always recommended to 

install softening and iron removal systems upstream. The 

company cannot be held responsible for issues related 

to the use of non-drinkable water or lack of installation 

of such systems. 

The plumber is responsible for choosing 

the type of components to be used and the verification 

of compliance with the purity and potability parameters 

of the water supply.

Installation

Summary of Contents for Zen Pro

Page 1: ...Zen Pro minipool Installation manual...

Page 2: ...ead this manual carefully before installing it The Treesse team is always available for any information or request for assistance that may be required during installation GRUPPO TRE S s p a Telephone...

Page 3: ...______ 10 2 QUALIFICATIONS OF THE INSTALLER ________________________________________________ 10 3 CONNECTIONS REQUIRED__________________________________________________________ 11 4 PLUMBING CONNECTIO...

Page 4: ...modifications that do not follow the information provided in this manual can cause damages injuries or fatal accidents and null and void the warranty During the installation of the minipool do not pl...

Page 5: ...in compliance with current regulations in force in the country of installation A drain a gate valve to shut off the supply water and drain valves have been installed to empty the minipool at the end...

Page 6: ...ys to reach the desired place of installation Movement must be carried out using personal protective equipment e g gloves safety shoes etc and taking all the necessary safety precautions for those inv...

Page 7: ...nipool into the prepared space If it was not possible to provide a technical inspection port on all sides of the minipool a pneumatic lift is available OPTIONAL to be requested from the Manufacturer i...

Page 8: ...e If necessary contact the Manufacturer for more details When filling is complete reposition the filter in its compartment and check that the connections are correct and that there are no leaks LEGEND...

Page 9: ...clean and verify that the gaskets are still in place INTERIOR top view Caution Make sure that the six internal filters are correctly positioned and secured see figure C A 1 3mm 1 3mm 23 cm 7 cm 1 3B...

Page 10: ...THE INSTALLER Before installation it is recommended to carefully read the safety warnings at the beginning of this manual and to always operate in perfect physical and mental condition The installer q...

Page 11: ...and plumbing connection to an exchanger optional if present see following page The following pages will provide detailed explanations of how to perform these preparations EXAMPLES OF OUTDOOR INDOOR MI...

Page 12: ...al connections Drain Loading supply Technical inspection port IN incoming hot domestic water OUT outgoing cold water 230V C S P in out PR TC EV BS P2 BL 1 BL2 HTR Cromo 230V EVc EVs EVclv 230V heater...

Page 13: ...Ideal values of alkalinity range between 80 mg L and 125 mg L 8 F 12 5 F Values outside of this range can more easily cause variations of the pH Instead alkalinity within the range noted makes it poss...

Page 14: ...le hose provided If the minipool is installed outdoors provide an adequate thermal insulation of the pipes It is the plumber s responsibility to choose the type of materials to be used Connect the dra...

Page 15: ...east 3 mm and a breaking capacity equal to 60A or in any case adequate for the absorption of the bathtub Controlled by a differential switch no larger than 30mA The control unit s power supply cable m...

Page 16: ...and properly connected to the pipes The water connections have been made properly in accordance with local and national codes and that they can guarantee a perfect seal verification to be carried out...

Page 17: ...maximum sensor does not detect water SL2 0 activates automatic filling until conditions are restored and for a maximum of 60 minutes If the lack of water is considerable e g two or more people get ou...

Page 18: ...east 2 3 minutes to expel the air that may be present in the plumbing system 4 WATER TEMPERATURE ADJUSTMENT When one of the two keys or is pressed once the display shows the current setting default 35...

Page 19: ...ctivate it When the function is activated the display will show the word LOCK for six seconds and then return to showing the water temperature To disable the function press the OK key again for three...

Page 20: ...hen the SILENCE function starts the SILENCE function remains suspended and will become active 10 minutes after the user function has been switched off If a user function is activated by the user while...

Page 21: ...recirculation pump from running in the event of potential danger It is activated when the recirculation pump is running the flow switch does not detect flow for at least five seconds The display show...

Page 22: ...es are not dirty 2 Water supply with low pressure make sure that the minipool s supply pressure is between 1 5 and 3 bar 3 Leaks in the bathtub s pipes make sure that there are no leaks in the bathtub...

Page 23: ...After the first cleaning of the bottom the problem should no longer exist Cleaning the bottom with a minipool cleaner Make sure you have used sand with granularity from 0 5 to 1 mm suitable for this t...

Page 24: ...24 Zen Pro minipool EN Mount the wood or laminate resin panels as shown in the figures below Decorative panels 1 2 3 1 3 2...

Page 25: ...Under these conditions or when not used advise the owner to use a fixed or mobile cover to protect the minipool we recommend the optional Treesse covers In addition to preserving the surfaces the cov...

Page 26: ...Notes Notes...

Page 27: ...e small differences between this manual and the product you have received we apologise in advance for any inconvenience The total or partial reproduction of this manual without the Manufacturer s cons...

Page 28: ...Zen Pro installation Edition 03 2018 www gruppotreesse it GRUPPO TRE S s p a 01036 Nepi VT Italy S S Cassia km 36 400 Settevene industrial area tel 39 0761 527242 fax 39 0761 527223 info gruppotres it...

Reviews: