18
Zen
Pro
minipool
EN
2
FIRST RUN
With the bathtub full, recirculation active and ozone
active, start in sequence all the functions of the bathtub
in the presence of the owner to verify proper operation:
1
BLOWER
The minipool can be equipped with:
A single blower motor (standard)
activates the nozzles on the bottom.
A second motor (optional)
activates
the nozzles
on the seat.
If there is only one blower motor, pressing the
1
key
starts the bottom nozzle operation (default duration
20 minutes).
The blower function on the bottom cannot be started
if the whirlpool is running.
If there are two blower motors (optional), pressing
the
1
key will activate the function, alternating the
two zones (bottom n seat nozzles) with an
interval of 30 seconds and always for a maximum
duration of 20 minutes.
The blower function on the seat can be started even
if the whirlpool is running.
When the
key is pressed again, the blower
function stops, the key returns to white and the
temperature is shown again on the display.
2
LYMPHODRAINING CHAISE LONGUE
WHIRLPOOL (OPTIONAL)
The function can only be activated if the whirlpool jets
are present in the seat on the command side. Press
the
2
key to start the function (default duration 20
minutes), press it again to stop it
3
PERIMETER WHIRLPOOL (BACK AND LEGS)
Pressing the
3
will activate the whirlpool function
in the two perimeter slots present in the minipool
(default duration 20 minutes). Press the key again to
stop the function. The first time it is recommended
to leave the whirlpool in operation for at least 2-3
minutes to expel the air that may be present in the
plumbing system.
4
WATER TEMPERATURE ADJUSTMENT
When one of the two keys
+
or
-
is pressed once,
the display shows the current setting (default 35°C) and
the two keys are illuminated with a strong blue light.
From the second press on, the displayed value is
increased or decreased by one degree at a time
depending on the key pressed (range from 15°C to
40°C).
After six seconds of inactivity with the keys or if
another key is pressed, the adjustment function will
end and the two keys will return to white, memorising
the new setting.
The function will activate the heater (flashing degree
character) with the objective of heating and maintaining
the water temperature at the set value (+/- 0.5°C).
First run
5
CHROMATHERAPY
Pressing the light key
5
activates a sequence of 16
colours that vary in an automatic sequence (default
duration two hours):
The light key
5
and the
+
and
-
keys turn blue and the display shows the
+
symbol for six seconds.
During this time you can press the
+
or
-
key
to manually select a colour that you want to remain
fixed:
the light key
5
will remain blue, while the
+
and
-
keys will turn white again: at this time it is no
longer possible to change colour.
To once again manually select the colour, press the
light key
5
again and select the desired colour
within six seconds with the
+
or
-
key.
Once you have selected a fixed colour, to return to the
automatic sequence you must turn off and reactivate
the function.
To stop the function hold the
key pressed for
about three seconds. The key will turn white again
and the temperature will reappear on the display.
The function can always be activated, even if the water
level is low.
OK
OK
3”
1
7
9
8
10
2
5
3
6
4
Submenu
page
Main page
Summary of Contents for Zen Pro
Page 1: ...Zen Pro minipool Installation manual...
Page 26: ...Notes Notes...