Page 10
IT-400 series instruction manual
ENGLISH
The control panel is protected against attempts to insert a false electronic key.
If a person inserts a wrong key 10 times, the internal siren relay (Terminals 9,10,11) and
external siren relay (Terminals 12,13,14,15,16,17) will be triggered for the alarm time
programmed.
7.3. ELECTRONIC KEY SABOTAGE
(IT-400 K only)
The IT-400 K may be armed and disarmed through the
electronic key situated on the front panel or with a remote
electronic key (optional). The control panel is supplied
with 2 electronic keys already coded .
The control panel can self learn and memorize up to 8
different codes. Available upon request there are also
receptacles for electronic key series Magic and Living.
On the receptacle there are 3 LEDs that signal control
panel full armed “On mode”, partially armed “Night mode”
and “DAY mode” (see figure on the right).
LED
"
Control panel armed ON
"
(Red)
Has the same functions as LED “
ON
” on the panel.
When the electronic key is inserted, the LED emits the
following signal:
1) Lit during exit time, after exit time has expired
flashes until panel is disarmed.
LED
"
Control panel armed Night mode
” (Red)
Has the same functions as LED “
NIGHT
” on the panel.
When the electronic key is inserted, the LED emits the following signal:
1) The LED will flash at the end of the exit time until panel is disarmed.
LED
"
DAY mode and Alarm Memory
" (Green)
1) When control panel is in "DAY" mode, the LED flashes.
2) This LED will light during the exit time if one of the 7 zones is triggered.
3) After an alarm trigger, this LED will light and remain lit until the control panel is
disarmed and re-armed. This is indication of alarm memory.
7.2. REMOTE RECEPTACLE INSTALLATION
To allow arming of the control panel from more then one
remote position it is necessary to wire up to terminals
33, 34, 35, 36 and 37 of the IT-400 K to the terminals on
the back side of the receptacle as shown in the figure on
the right.
Control
panel
armed
ON
Control panel
armed Night
Remote
receptacle
Electronic
key
Control panel
disarmed
(DAY) and
alarm mem-
Receptacle
on front panel
7.1. ELECTRONIC KEY (IT-400 K only)
Terminal block
of the control
panel
re m o to
Inse rito re
33
37
36
35
34
Page 11
IT-400 series instruction manual
ENGLISH
8.0.
MECHANICAL SWITCH LOCK KEY
(remote)
The IT-400 and IT-400 D may be remote armed/disarmed by means of a switch lock
connected to terminals 33 and 34.
Using a remote switch lock only total arming/disarming is possible (ON position and
Day position). Night arming is not possible
.
If the control panel has been armed with a remote mechanical switch lock (Terminals
33 and 34 open), it is possible for the control panel to be disarmed by means of the
front panel key (or numeric code for IT-400 D) or the remote switch lock
.
If the control panel has been armed with the front panel key or by numeric code (IT
-400 D) and you attempt to change the status with the remote switch lock, the con-
trol panel will not respond anymore to the remote switch lock
.
9.0. MAINTENANCE MODE
With the control panel in this mode it is possible to:
1)
Open the control panel without triggering an alarm
2)
Re-set to factory codes (IT-400 K and IT-400 D only)
3) Enter
into
the
programming mode
To enter into Maintenance
With cover open:
Set switch 1 of dip switch A to ON for programming. The LED “ON”
and “NIGHT” will flash to indicate maintenance mode.
With
cover
closed (panel already installed)
:
Set the panel in ON mode (with the master
key in IT-400 K) and during the exit time open the cover and set
switch 1 of dip-switch A to ON for programming. The LED “ON” and
“NIGHT” will flash to indicate maintenance mode.
To exit Maintenance mode
Finished the maintenance operations set switch 1 of dip-switch A to OFF and during the
exit time close the cover and set the panel in "DAY" mode.
NOTE
:
If at the end of the exit time the panel key is still in ON mode, it will automatically
arm.