Page 10 

IT-400 series instruction manual 

ENGLISH 

 

The control panel is protected against attempts to insert a false electronic key. 

 

 

If a person inserts a wrong key 10 times, the internal siren relay (Terminals 9,10,11)  and 
external siren relay (Terminals 12,13,14,15,16,17) will be triggered for the alarm time     
programmed.   

7.3.  ELECTRONIC KEY SABOTAGE  
        (IT-400 K only) 

   The IT-400 K may be armed and disarmed through the 
electronic key situated on the front panel or with a remote 
electronic key (optional). The control panel is supplied 
with 2 electronic keys already coded .  
   The control panel can self learn and memorize up to 8    
different codes. Available upon request  there  are  also    
receptacles for electronic key series Magic and Living.  
   On the receptacle there are 3 LEDs that signal control 
panel full armed “On mode”, partially armed “Night mode” 
and “DAY mode” (see figure on the right).  

 

LED 

"

Control panel armed ON

"

 

(Red) 

  

Has the same functions as  LED “

ON

” on the panel.  

 

When the electronic key is inserted, the LED emits the 
following signal: 

 

1)  Lit during exit time, after exit time has expired 
 

flashes until panel is disarmed. 

 

LED

 "

Control panel armed Night mode

” (Red) 

  

Has the same functions as  LED “

NIGHT

” on the panel.  

 

When the electronic key is inserted, the LED emits the following signal: 

 

1)  The LED will flash at the end of the exit time until panel is disarmed.  

 

LED 

"

DAY mode and Alarm Memory

" (Green)  

 

1)  When control panel is in "DAY" mode, the LED flashes.  

 

2)  This LED will light during the exit time if one of the 7 zones is triggered. 

      3)   After an alarm trigger, this LED will light and remain lit until the control panel is         

 

disarmed and re-armed. This is indication of alarm memory. 

7.2. REMOTE RECEPTACLE INSTALLATION 

To allow arming of the control panel from more then one    
remote position it is necessary to wire up to terminals 
33, 34, 35, 36 and 37 of the IT-400 K to the terminals on 
the back side of the receptacle as shown in the figure on 
the right. 

 

Control 

panel  

armed 

ON  

Control panel 

armed Night  

Remote  

receptacle 

    Electronic 

              key  

Control panel  

disarmed  

(DAY) and 

alarm mem-

      Receptacle  

  on front panel 

7.1.  ELECTRONIC KEY (IT-400 K only) 

Terminal block 

of the control  

panel 

re m o to

Inse rito re

33

37

36

35

34

Page 11 

IT-400 series instruction manual 

ENGLISH 

8.0. 

MECHANICAL SWITCH LOCK KEY 

(remote) 

   The IT-400 and IT-400 D may be remote armed/disarmed by means of a switch lock         
connected to terminals 33 and 34. 
 

 

Using a remote switch lock only total arming/disarming is possible (ON position and 
Day position). Night arming is not possible

.  

 

If the control panel has been armed with a remote mechanical switch lock (Terminals 
33 and 34 open), it is possible for the control panel to be disarmed by means of the 
front panel key (or numeric code for IT-400 D)  or the remote switch lock

 

If the control panel has been armed with the front panel key or by numeric code     (IT
-400 D) and you attempt to change the status with the remote switch lock, the  con-
trol panel will not respond anymore to the remote switch lock

9.0.  MAINTENANCE MODE 

With the control panel in this mode it is possible to:

   

1) 

Open the control panel without triggering an alarm 

 

2) 

Re-set to factory codes (IT-400 K and IT-400 D only)  

 

3) Enter 

into 

the 

programming mode  

 

To enter into Maintenance

  

 

 

With cover open:  

Set switch 1 of dip switch A to ON for programming. The LED “ON” 

 

and “NIGHT” will flash to indicate maintenance mode. 

 With 

cover 

closed (panel already installed)

:

 

Set the panel in ON mode (with the master 

 

 

key in IT-400 K) and during the exit time open the cover and set 

 

 

switch 1 of dip-switch A to ON for programming. The LED “ON” and 

 

 

“NIGHT” will flash to indicate maintenance mode. 

 

  

To exit Maintenance mode

 

 

 

Finished the maintenance operations set switch 1 of dip-switch A to OFF and during the 
exit time close the cover and set the panel in "DAY" mode. 

 
NOTE

:

  If at the end of the exit time the panel key is still in ON mode, it will automatically 

arm.

  

Summary of Contents for IT-400

Page 1: ...indicates control panel armed day position This is located on the remote electronic key base see page 10 36 Output for remote LED that indicates alarm memory This is located on the remote electronic...

Page 2: ...relay alarm outputs Separate relay alarm outputs for internal sirens Remote indication for unit ON Low battery indication Output for siren with or without battery back up Relay output for panic an fi...

Page 3: ...mains fuse and if the battery charger is functioning correctly 13 8 Vdc on cables of battery If all functions correctly then the battery must be replaced Please dispose of faulty batteries in an envir...

Page 4: ...C Outdoor siren relay 33 Buzz Remote Key Impulse Remote Key ON OFF Page 17 IT 400 series instruction manual ENGLISH To disarm the panel IT 400 Rotate the key in DAY position IT 400 K Insert the key in...

Page 5: ...e will cause Flashing of the corresponding LED on the front panel until the control panel is re armed to signal Alarm memory Lighting of the DAY LED on the front panel and on receptacle of electronic...

Page 6: ...g the exit time the following will take place The ON LED on the panel and electronic key receptacle will light If however there are zones open or unbalanced the LED of the triggered zone on the panel...

Page 7: ...the control panel to DAY mode 13 0 BY PASSING ZONES It is possible to partially arm the system NIGHT mode by by passing some of the zones NOTE The control panel is supplied with all the zones active P...

Page 8: ...ight 1 Off signals line closed normal status 2 Flashing indicates zone in alarm or alarm memory L BAT FIRE PANIC AS POWER L BAT FIRE PANIC AS POWER L1 L2 L3 L4 L1 L2 L3 L4 D C A B ON DAY ON NIGHT DAY...

Page 9: ...the cover of the control panel making sure that dip 1 of dip switch A is in OFF position normal function and that the tamper button is closed Page 9 IT 400 series instruction manual ENGLISH ATTENTION...

Page 10: ...0 K to the terminals on the back side of the receptacle as shown in the figure on the right Control panel armed ON Control panel armed Night Remote receptacle Electronic key Control panel disarmed DAY...

Reviews: