8
Installation
(for qualified installers only)
Travis Industries
4 0 2 0 8 1 2
9 3 5 0 8 1 1 0
Clearances
•
When installed, walls in front of the fireplace must be a minimum 6" to the side of the faceplate.
•
Fireplace must be placed so that no combustibles are within, or can swing within 36" of the front of
the fireplace (e.g. drapes, doors)
•
Fireplace must be placed so the vents below and above the glass do not become blocked
Corner Installations
A typical 45° installation uses the minimum framing dimensions shown in the illustration below.
AA
AA
AA
AA
AA
A
A
A
A
A
A
A
A
A
A
AAAAAAAAAA
19-3/8"
1" Standoffs
Min. 1" Clearance to
Fireplace Enclosure
47-5/8"
13-3/4"
14-3/4"
10" Diameter Pipe
(7" Length)
7"
AAA
AAA
AAA
AA
AA
A
A
A
A
A
A
A
A
A
AAAAAAAAA
45° Elbow
Thimble
(opening is 14-1/2"
high x 13" wide)
DVL Fireplace
50-1/2"
Termination
MinimumClearances from
Pipe To Combustibles:
• 1-1/2" to the Sides & Below
• 3" Above
Top Vent Configuration
Rear Vent Configuration
NOTE:
the fireplace may require a
larger enclosure to allow for
the vent to pass through the
framing.
1-1/2" (min. clearance)
Raised Fireplaces
•
The fireplace (and hearth, if desired) may be placed on a platform designed to support the fireplace
(approximately 300 Lbs.) and vent.
•
The fireplace may not be raised so as to place the ceiling within 24” of the top of the faceplate.
Raised fireplace
Raised fireplace with
raised hearth.
Raised
Platform
Nail the nail down plates to the floor
(or raised platform)
Raised Hearth
Hearth
Raised
Platform