background image

180-CL2714.IPI v1.01

April 21, 2021

Pour la version française de nos manuels S.V.P. vous référez à notre site web: www.blazeking.com

CLARITY CL2714.IPI

Date  Installed:

Serial No.:

Installer: Please complete the details on the back cover and leave this manual with the  

 

 homeowner.
Homeowner: Please keep these instructions for future reference.

WARNING:  If the information in these instructions are not followed exactly, a 

fi

 re or 

explosion may result causing property damage, personal injury or loss of life.

PFS report#:F18-431

A safety screen designed to reduce the risk of burns from 
the hot viewing glass is provided with this appliance and 
shall be installed for the protection of children and other 
at-risk individuals.  If the safety screen becomes damaged, 
the safety screen shall be replaced with the manufacturer’s 
safety screen for this appliance.

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings 

exactly could result in serious injury, 

death, or property damage.

— 

Do not store or use gasoline or other  

 

fl

 ammable vapors and liquids in the  

 

 

vicinity of this or any other appliance.

—  

 

WHAT TO DO IF YOU SMELL GAS

• 

Do not try to light any appliance.

• 

Do not touch any electrical switch; do not 
use any phone in your building.

• 

Leave the premises.

• 

Immediately call your gas supplier from a 
neighbor’s phone. Follow the gas supplier’s 
instructions.

• 

If you cannot reach your gas supplier, call 
the 

fi

 re department.

— 

Installation and service must be 

performed by a quali

fi

 ed installer, service agency 

or the gas supplier.

This appliance may be installed in an aftermarket, 
permanently located, manufactured home (USA only) or 
mobile home,  where not prohibited by local codes.

This appliance may be installed in an OEM Installation in a 
manufactured home (USA only) or mobile home and must be 
installed in accordance with the manufacturer’s instructions 
and the Manufactured Home Construction and Safety 
Standard, Tittle 24 CRF, Part 3280, in the United States, or the 
Standard for Installation in Mobile Homes, CAN/CSA Z240 MH 
Series, in Canada.

This appliance is only for use with the type of gas indicated 
on the rating plate.  This appliance is not convertible for use 
with other gases, unless a certi

fi

 ed kit is used.

DIRECT VENT GAS FIREPLACE INSERT

with Intermittent Pilot Ignition (IPI)

For use with natural gas (NG) or propane (LPG)

OPERATION & INSTALLATION MANUAL

Summary of Contents for CLARITY CL2714.IPI

Page 1: ...y other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the premises Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer...

Page 2: ...E FIREPLACE 13 INSTALLATION CLEARANCES___________________________________________________________ 14 MINIMUM FIREPLACE DIMENSIONS 15 OPTIONAL BLOWER_____________________________________________________________________ 16 S Z5277 IPI BLOWER INSTALLATION 16 INSTALLATION___________________________________________________________________________ 18 INITIAL SETUP 18 VENT TERMINATION LOCATION 19 VENTING...

Page 3: ...ose one S Z4981 CL2714 SHROUD 24 5 x 36 5 S Z4982 CL2714 SHROUD 26 5 x 38 S Z4983 CL2714 SHROUD 29 x 40 S Z4984 CL2714 SHROUD 32 x 44 S Z4985 CL2714 SHROUD 32 x 44 TRIMMABLE OPTIONAL KITS S 0402 CL2714 FIREBOX GLASS KIT 3PC S 0602 CL2714 FIREBOX GLASS KIT 4PC S 0519 LOG SET DRIFT CLARITY 5PC S 0529 LOG SET DRIFT CL2714 7PC S Z4990 CL2714 SHELF WITH RISERS S Z4991 CL2714 MANTEL SHIELD 40 S Z4992 CL...

Page 4: ...ividuals in the house To restrict access to a fireplace or stove install an adjustable safety gate to keep toddlers young children and other at risk individuals out of the room and away from hot surfaces Any safety screen guard or barrier removed for servicing an appliance must be replaced prior to operating the appliance Clothing or other flammable materials should not be placed on or near the ap...

Page 5: ...ng envelope Never vent to another room or inside the building Make sure the specified vent pipe is used properly sized and of adequate height to provide sufficient draft The flow of combustion and ventilation air must not be obstructed The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in ...

Page 6: ...aller This appliance is certified for installation in a bedroom or a bedsitting room This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes This appliance is not convertible for use with other gases unless a certified kit is used Only for direct dischar...

Page 7: ...180 CL2714 IPI v1 01 April 21 2021 Page 7 Clarity CL2714 IPI CERTIFICATION LABEL ...

Page 8: ...building at a minimum height of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equ...

Page 9: ...CATION The rating label is located below the firebox behind a flip down door It is affixed to rectangular metal sheets that are chained to the appliance NOTE TURNING ON YOUR APPLIANCE WHEN IT HAS BEEN OFF FOR AWHILE MAY CAUSE TEMPORARY CONDENSATION TO APPEAR ON THE GLASS THIS IS A NORMAL OCCURRENCE AS YOUR APPLIANCE HEATS UP UNIT DIMENSIONS SHOWN WITH SAFETY SCREEN TRIM AND SECONDARY TRIM ...

Page 10: ...L2714 IPI v1 01 April 21 2021 Page 10 Clarity CL2714 IPI SHROUD AND SHELF OPTIONS S Z4981 CL2714 SHROUD 24 5 x 36 5 S Z4982 CL2714 SHROUD 26 5 X 38 S Z4983 CL2714 SHROUD 29 x 40 S Z4984 CL2714 SHROUD 32 x 44 ...

Page 11: ...arity CL2714 IPI SHROUD AND SHELF OPTIONS S Z4985 CL2714 SHROUD 32 x 44 TRIMMABLE S Z4990 CL2714 45 SHELF W RISERS REQUIRES CL2714 SHROUD S Z4994 CL2714 ANGLED SHROUD BASE REQUIRES S Z4981 CL2714 SHROUD 24 5 x36 5 OR S Z4982 CL2714 SHROUD 26 5 x38 ...

Page 12: ...manual shutoff ball valve The inlet has a 1 2 female pipe thread SHUT OFF VALVE LOCATION Use present location of shut off valve if the fireplace size provides adequate clearance or if size is restricted move the shut off valve underneath firebox THE APPLIANCE AND ITS INDIVIDUAL SHUTOFF VALVE MUST BE DISCONNECTED FROM THE GAS SUPPLY PIPING SYSTEM DURING ANY PRESSURE TESTING OF THAT SYSTEM AT TEST PRES...

Page 13: ... Chimney clean outs must fit properly Check local codes whether a continuous length is required or if certified joiner kits may be used Minimum 8 ft Maximum 36 ft Flashing Co linear DV vertical termination cap Air Intake Exhaust Flue FACTORY BUILT FIREPLACE OR ZERO CLEARANCE FIREPLACE Ensure that there is a minimum base of sheet metal below the unit upon installation along with supplied levelling ...

Page 14: ...4991 mantel shield and 12 mantel With S Z4992 mantel shield and 12 mantel With S Z4992 mantel shield and 5 mantel 48 1219 mm 40 1016 mm 34 864 mm 32 813 mm C Maximum mantel depth 12 305 mm D Minimum ceiling clearance from bottom of unit 67 5 1715 mm NOTE CHECK LOCAL CODES FOR FLOOR REQUIREMENTS THIS FIREPLACE IS SUITABLE ONLY FOR INSTALLATION IN A MASONRY OR FACTORY BUILT FIREPLACE PD PD PD 1 5 67...

Page 15: ... 565 mm Width front E 29 25 743 mm COMBUSTIBLE FLOOR IN FRONT CAN BE LEVEL WITH HEARTH AND CL2714 LEVELING BOLTS MUST BE INSTALLED MINIMUM FIREPLACE DIMENSIONS The minimum fireplace dimensions the this insert are in the following diagrams and chart INSTALLATION CLEARANCES NOTE MUST ACCOUNT FOR AN ADDITIONAL 3 5 8 OF CLEARANCE TO THE RIGHT SIDE OF UNIT FOR IFC BOARD ...

Page 16: ...prior to appliance installment by removing the back blower access cover If the appliance is already installed go to step 5 3 Affix the blower to the access cover as shown the blower edge should be against the cover flange 4 Feed blower wires and assembly through opening and reattach the access cover go to step 8 5 Slide label plates out and set them to the side 6 Slide blower through left hand side ...

Page 17: ...wires to the right hand side 8 Align the wire grommet slot with the slot on the appliance then feed the blower connector through the slots 9 Rotate the wire grommet so the slots are offset and all the wires are contained 10 Insert the blower connector into the IFC board 11 Re hang safety screen and face frame if applicable 12 See ELECTRICAL REQUIREMENTS for wiring diagram ...

Page 18: ... safety screen trim aside 3 REMOVE THE STATIC CLING LABEL THAT IS ON THE DOOR GLASS Hold glass to frame when removing as it is only held in place with silicone Set the door glass assembly aside 4 If installing the optional S 0402 FIREBOX GLASS KIT 3 piece or the S 0602 FIREBOX GLASS KIT 4 piece then refer to their respective installation instructions 5 If installing the optional S 0519 LOG SET DRI...

Page 19: ...l pipe Clearances are in accordance with local installation codes and the requirements of the gas supplier Other installations The total vertical height up to 36 10 97 m maximum Use vent restrictor on vents from 20 6 09 m to 36 10 97 m to obtain optimal flame appearance see VENT RESTRICTOR and BURNER FLAME APPEARANCE NOTE Maximum vent lengths may be subject to local codes For best venting performa...

Page 20: ...ut the top and tie off if necessary Ensure the flex vent is stretched as needed 2 Unscrew the 1 4 20 bolt from the vent connector slide plate Fig 2 and remove to attach to the flex vents WITH HOSE CLAMPS as shown below 3 Adjust the flex vent until the vent connector is at the same height as the insert 4 Slide the insert into place guide the vent connector slide plate into the guides on the top of t...

Page 21: ... can be adjusted as follows 1 Turn off the appliance and allow it to cool down completely 2 Remove the safety screen trim and glass door set aside see SAFETY SCREEN TRIM AND GLASS DOOR REMOVAL 3 Move the restrictor tab off of the restrictor index plate Fig 5 4 Adjust the restrictor index plate to one of the slots to obtain desired flame and reset the restrictor tab into the restrictor index plate sl...

Page 22: ...herefore the air shutter should be closed slightly until the correct flames are achieved Slide the air shutter to the right to reduce the amount of air 5 Flames that are very orange with tall dark stringy tips are not getting enough air Therefore the air shutter should be opened slightly until the desired flames are achieved Slide the air shutter to the left to increase the amount of air 6 Tighten...

Page 23: ...TO THIS UNIT LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION VERIFY PROPER OPERATION AFTER SERVICING 600 584 665 PF2 IFC BOARD 135 0170 18 x2 140 0294 x3 140 3611 03 WIRE BOARD CONNECTOR GROUND 140 176 699 X4 PLUG 135 0159 B 2 BOTH ENDS CONNECTED INTO PLUG 600 584 045 PROFLAME TRANSMITTER 12 blk 12 white 140 178 619 FAN CONNEC...

Page 24: ...any gas control which has been under water LIGHTING INSTRUCTIONS 1 STOP Read the safety information above 2 Set the thermostat to the lowest setting 3 Turn off all electric power to the appliance 4 Do not attempt to light the pilot by hand 5 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above If you don ...

Page 25: ... ON OFF solenoid EV1 terminals 2 ON OFF solenoid EV2 terminals 3 Inlet pressure test point 4 Outlet pressure test point 5 c Electrical pressure modulator device 6 Pressure modulator device terminal 7 Pilot adjusting screw 8 Pilot outlet 9 Gas inlet with protective seal 10 Gas outlet with protective seal 11 Ground connection 12 Mounting holes ...

Page 26: ... MOUNT TRANSMITTER REMOTE OPERATION Intermittent Pilot Ignition IPI The Proflame 2 Transmitter is an integrated part of the Proflame 2 System which consists of these elements A Proflame 2 wall mount transmitter remote and an Integrated Fireplace Controller IFC with a wiring harness that connects to the gas valve stepper motor and convection fan The Proflame Transmitter provides for controlling the...

Page 27: ... the mounting hardware supplied with the remote control Insert the remote control onto the adapter Fig 4 OPERATING PROCEDURE Initializing the System for the First Time Power the IFC control Install the 3 AAA type batteries in the Transmitter battery bay located on the base of the Transmitter Fig 5 With the batteries already installed in the Transmitter push the red sync button on the IFC control N...

Page 28: ...room temperature Fig 8 At the same time the Receiver will turn off the appliance A single beep from the Receiver confirms reception of the command Remote Flame Control The proflame has six 6 flame levels With the system on and the flame level at the maximum in the appliance pressing the Down Arrow Key once will reduce the flame height by one step until the flame is turned off The Up Arrow Key will i...

Page 29: ...et temperature is displayed on the LCD screen of the Transmitter Fig 11 Smart Thermostat Transmitter Operation The Smart Thermostat function adjusts the flame height in accordance to the difference between the set point temperature and the actual room temperatures As the room temperature gets closer to the set point the Smart Function will modulate the flame down To activate this function press the...

Page 30: ...ex to the blower control icon Fig 13 Use the Up Down Arrow Keys Fig 1 to turn on off or adjust the blower speed Fig 14 A single beep will confirm reception of the command Fig 13 Fig 14 Remote Auxiliary Relay Control The auxiliary function controls the AUX relay outlet To activate this function use the Mode Key Fig 1 to index to the AUX icon Fig 15 16 Pressing the Up Arrow Key will activate the outl...

Page 31: ...the reception of the command Fig 17 Fig 18 Key Lock This function will lock the keys to avoid unsupervised operation To activate this function press the MODE and UP Keys at the same time Fig 19 To de activate this function press the MODE and UP Keys at the same time Fig 19 Low Battery Power Detection The life span of the remote control batteries depends on various factors quality of the batteries ...

Page 32: ...URFACES Painted powder coated or porcelain enameled surfaces should be wiped with a damp cloth periodically Ensure the appliance has cooled down completely before any cleaning Do not use other cleaners as they may leave a residue which can become permanently etched into the surface CLEANING THE GLASS DO NOT TO CLEAN THE GLASS WHILE IT IS HOT One of the by products of combustion and moisture in the...

Page 33: ...fety screen trim up and out away from the appliance and set it aside Fig 1 GLASS DOOR REMOVAL For installation cleaning and burner removal the safety screen trim see SAFETY SCREEN TRIM REMOVAL and glass door must be removed 1 There are two door latch mechanisms on top of the glass door Fig 2 Pull the tabs forward and up off the door tabs 2 Carefully slide the door glass assembly up and out of the u...

Page 34: ...lass from the door must be done by a qualified service technician The glass door must be purchased from a Blaze King dealer No substitute materials are allowed BURNER REMOVAL 1 Turn off the appliance and allow it to cool down completely 2 Remove the safety screen trim and glass door see SAFETY SCREEN TRIM AND GLASS DOOR REMOVAL on previous page 3 Remove the floor glass if applicable and floor plate...

Page 35: ...16305 for Z4921 Safety Screen Trim 1 Turn off the appliance and allow it to cool down completely 2 Remove the safety screen trim by lifting up and out see SAFETY SCREEN TRIM REMOVAL 3 Slide the safety screen out of the frame the tabs may have to be adjusted Fig 6 4 Slide the new safety screen in between the frame face and the tabs Ensure screen mesh faces out furthest from glass Fig 7 5 Hang the sa...

Page 36: ...e 635 977 168 PF2 LP pilot orifice and LP regulator S Z0771 NG 635 OR41 41 orifice 635 977 166 PF2 NG pilot orifice and NG regulator Conversion kit labels To convert from NG to LPG or reverse 1 Turn off the appliance and allow it to cool down completely 2 Remove burner see BURNER REMOVAL 3 Replace main orifice 4 Convert pilot fuel see next page 5 Replace regulator see instuctions after pilot conver...

Page 37: ...om pilot using a 4 mm allen key Fig 9 then screw in the new orifice Fig 10 3 Align the pilot hood with the tab and re attach the pilot hood to the spring clamp 4 Fill out the fuel conversion label and affix to the firebox floor All valves have been pre set and certified for installation at elevations from 0 4500 feet or 1 1372 m above sea level Fig 8 Fig 9 Fig 10 MAINTENANCE and SERVICE ...

Page 38: ...180 CL2714 IPI v1 01 April 21 2021 Page 38 Clarity CL2714 IPI MAINTENANCE and SERVICE ...

Page 39: ... set is being used note locations remove and set aside 4 Undo the inlet gas lines from valve Fig 1 5 Disconnect all electrical connections to valve including ground wire 6 Back off the four screws on the two brackets holding the valve Fig 2 7 Lift the valve up and out 8 Installation is the reverse order of the previous steps NOTE WHEN INSTALLING A NEW VALVE CHECK THAT ALL UNUSED PORTS ARE PLUGGED C...

Page 40: ...DVA VCH 991 Square Horizontal Termination Cap aluminum 46DVA HC Square Horizontal Termination Cap stainless steel 46DVA HC S Square Horizontal Termination Cap copper 46DVA HC C Horizontal Square Termination Cap 984 ICC PARTS LIST DESCRIPTION PART CO LINEAR ALUMINUM FLEX KITS Standard 3 x3 Co linear Flex Kit Includes TM IVT TF MFR two 35 lengths of 3 diameter 2 ply AL flex TM ALK33 Traditional 3 x3...

Page 41: ...ACK CAP PROFORM INSERT CO LINEAR NON INSULATED KITS 94203360 3 X 3 VCL PRO FORM KIT 30 X 2 94203360B 3 X 3 VCL PRO FORM KIT 30 X 2 W BLACK CAP INSERT CO LINEAR TERMINATION CAPS 940033 3 X 3 VCL PRO FORM TERM CAP 940033B 3 X 3 VCL PRO FORM TERM CAP BLACK 940033C 3 X 3 VCL PRO FORM TERM CAP COPPER VERTICAL CO LINEAR TEMINATION CAPS W SS BASE 9400330808SS 3 X3 VCL PRO FORM TERM CAP W 8X8 SS BASE 9400...

Page 42: ...le 3 x3 Co Linear Cap Galvanized and Powder Coated Black VDV VCCH33 3 x3 High Wind Co Linear Cap VDV HC04 Horizontal Cap VDV VCH04 Vertical Termination Cap VDV VCC33 Vertical Round High Wind VDV CC33 Vertical Square Cap VDV CTT04 3 Co linear to Coax Adapter VDV CAC04 4 Co linear Appliance Adapter SELKIRK PARTS LIST PRODUCT NUMBER PART DESCRIPTION 4 x 6 5 8 ADAPTERS 1604245B 4DT AA Appliance Adapte...

Page 43: ...OOR PLATE 3 640 4900 14 WIDE BURNER 4 610 199 059 PF2 PILOT ASSEMBLY 5 Z4917 CL2714 DOOR ASSEMBLY 6 4980 SECONDARY TRIM 7 645 1630 SAFETY SCREEN 16 X 30 5 8 S Z4921 SAFETY SCREEN TRIM w SCREEN 9 Z4927 VALVE ASSEMBLY WITH BURNER 10 600 885 809 IPI VALVE WITH STEPPER MOTOR 11 140 5006 BATTERY HOLDER 4 AA 6V 12 600 584 665 IFC BOARD ...

Page 44: ...stem is reset 2 Low battery condition 4V the LED indicator will blink one 1 time in intervals 3 Parasitic Pilot Flame the LED indicator will blink two 2 times in intervals 4 System Lock out the LED indicator will blink three 3 times in intervals Additional Ignition Information 1 The Proflame2 IFC will try two 2 times for ignition 2 Each try for ignition will last approximately 60 seconds 3 The wai...

Page 45: ...ings and connections to the board Check the pilot burner for obstruction Check the wirings and connections between the pilot assembly and the board Check the correct gas type settings on the valve and pilot burner assembly orifice Pilot will not remain lit Problem with Flame Sensor circuit Check for proper connection of the Flame Sensor to the IFC board Check pilot for full flame impingement aroun...

Page 46: ...ent on thermopile Flame lifting Leak in vent pipe Check for leaks in vent connections Improper vent configuration Check vent configuration with manual Terminal may be re circulating flue gases Check to see if terminal is on correctly May need to install high wind termination cap Contact dealer Blue Flames The heater has just been started Normal during start up flame will yellow as the fireplace he...

Page 47: ...placement parts Warranty Period Components Covered Parts Labor Gas 1 Year X All parts materials and surface finishes flaking and peeling Except as covered by Conditions Exclusion and Limitations listed 2 Years X Igniters Thermocouple Thermopile Molded Refractory Panels Log sets Fan assembly Ignition components Gas valve Burner components Thermostat 5 Years 2 Years X Firebox Heat Exchanger 10 Years...

Page 48: ... and exclusions apply to this warranty Limited One 1 Year Warranty Under this warranty Blaze King covers all exterior surface finishes against defects in materials and workmanship for part repair or replacement and limited labor for the first 1 year to the original purchaser Please see the exclusions and limitations section below as certain restrictions and exclusions apply to this warranty How th...

Page 49: ...n this stove If unsure as to the extent of this Limited Warranty contact your authorized Blaze King dealer before installation 9 Blaze King will not be responsible for inadequate performance caused by environmental conditions 10 The Limited Warranty does not cover installation and operational related problems such as use of downdrafts or spillage caused by environmental conditions Environmental co...

Page 50: ...table Blaze King will not be liable for travel costs for service work In the event of in home repair work the customer will pay any in home travel fees or service charges required by the Authorized Dealer 27 At no time will Blaze King be liable for any consequential damages which exceed the purchase price of the unit Blaze King has no obligation to enhance or modify any stove once manufactured exa...

Reviews: