Finalizing the Installation
(for qualified installers only)
Travis Industries
4060623
100-01170
7. Check the air shutter following the directions below.
Air Shutter Adjustment
Let the heater burn for fifteen minutes (make sure the logs and glass are in place). The flames should
be yellow with no sooting. Adjust the air shutter, if necessary, to achieve the correct looking flame.
Correct
Flames should be blue at the
base, yellow-orange on the top.
If the flames are too tall or sooty on the
ends, open the air shutter.
Not Enough Air
If the flames are all blue and
short, close the air shutter.
Too Much Air
How to Adjust the Air Shutters
Both the front and rear burner air shutters are accessed by removing a cover plate (see the illustration
below). After adjusting the air shutter, replace the burner, logs, and glass and verify the flame quality.
Front Burner Air Shutter
Rear Burner Air Shutter
Air Shutter Cover
This gap is the air shutter opening.
Loosen this screw to rotate the
air shutter. Tighten the screw
once in place.
Air Shutter
Suggested Min. Air Shutter Settings: NG (factory setting) LP
Front Burner
Closed
1/3 Open
Rear Burner
1/16”
2/3 Open
8. Adjust the flame height to its highest position - the flames should not contact the top of the
firebox. Check the flame on lowest position. The flames should burn off each burner hole. If
the heater does not work correctly, contact your Travis dealer for a remedy.
9. Give this manual to the home owner for future reference and fully explain operation of this
heater. For comprehensive operating and maintenance instructions, refer to the Owner's
Manual (part # 100-01168).