Installation
(for qualified installers only)
Travis Industries
4060623
100-01170
Fireplace Placement Requirements
•
The fireplace requires a 4" clearance from the sides and 2” from the back of the fireplace to the
framing members. No material (insulation, framing, etc.) may be placed into this area.
•
Fireplace must be placed in a room with a minimum 96” ceiling.
•
Fireplace must be placed directly on a 1/2” layer of non-combustible cement board (or
equivalent).
•
Fireplace must be installed on a level surface capable of supporting the fireplace and vent.
•
This heater may be placed in a bedroom. Please be aware of the large amount of heat this
appliance produces when determining a location.
Clearances
•
When installed, walls in front of the fireplace must be a minimum 10-1/4” from the glass frame
(4-1/4" from the side stand-offs - see Figure 3).
•
Due to the high temperature, the heater should be located out of traffic and away from furniture
and draperies.
•
Fireplace must be placed so the vents below and above the glass do not become blocked.
Raised Fireplaces
•
The fireplace (and hearth, if desired) may be placed on a platform designed to support the
fireplace 250 Lbs.) and vent.
AAAAA
AAAAA
AAAAA
AAAAA
AAAA
AAAA
AAAA
AAAAAAAAAAA
AAAAAAAAAAA
AAAAAAAAAAA
AAAAAAAAAAA
AAAAAAAAAAA
AAAAAAAAAAA
AAAAAAAAAAA
Platform (with
cement board)
AAAAAAA
AAAAAAA
AAAAAAA
AAAAAAA
AAAAAAA
AAAAAAA
AAAAAAA
AAAAAAA
AAAAAAA
AAAAAAA
AAA
AAA
AAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
AAA
AAA
AAAAAA
AAAAAA
AAAAAA
AAAAAA
AAA
AAA
AAA
AAAA
AAAA
AAAA
Min. 82”
Fireplace
Enclosure
Height
Optional Raised Hearth
(see “Hearth Requirements” for details)
Figure 6