Adjunct to ASTM E XXXX Wood Heater Cordwood Test Method - May 10, 2017 Version
Cordwood Fuel Load Calculators - 12 lb/ft
3
Nominal Load Density
Core 45-65% of Total Load Weight, Remainder 35-55% of Total Load Weight
Values to be input manually
For Usable Firebox Volumes up to 3.0 ft
3
- Low and Medium Fire
Nominal Required Load Density (wet basis)
12
lb/ft
3
Usable Firebox Volume
2.43 ft
3
Total Nom. Load Wt. Target
29.16 lb
Total Load Wt. Allowable Range
27.70
to
30.62
lb
Core Target Wt. Allowable Range
13.122
to
18.95
lb
Remainder Load Wt. Allowable Range
10.21
to
16.04
lb
Mid-Point
Core Load Fuel Pc. Wt. Allowable Range
4.37
to
7.29
lb
5.83
Remainder Load Pc. Wt. Allowable Range
2.92
to
8.75
lb
5.83
Fuel Piece Moisture Reading (%-dry basis)
Pc. #
1
2
3
Ave.
Core Load Piece Wt. Actual
1
4.91 lb
In Range
22.6
18.4
24.5
21.8
In Range
4.03
lb
1.83
kg
2
4.59 lb
In Range
23.6
18
22.1
21.2
In Range
3.79
lb
1.72
kg
3
4.68 lb
In Range
19.9
17.5
22.7
20.0
In Range
3.89
lb
1.77
kg
Core Load Total. Wt. Actual
14.18 lb
In Range
Pc. #
Remainder Load Piece Wt.
1
4.56 lb
In Range
24.5
23.2
17.1
21.6
In Range
3.75
lb
1.70
kg
(2 or 3 Pcs.)
2
6.42 lb
In Range
20.3
17.2
23.3
20.3
In Range
5.33
lb
2.42
kg
3
3.93 lb
In Range
19.8
25
17.2
20.7
In Range
3.26
lb
1.48
kg
Remainder Load Piece Weight Ratio - Small/Large
61%
In Range
≤ 67%
Total Load Ave. MC % (dry basis)
20.9
In Range
Remainder Load Tot. Wt. Act
14.91 lb
In Range
Total Load Ave. MC % (wet basis)
17.3
Total Load Wt. Actual
29.08 lb
In Range
Total Test Load Weight (dry basis)
24.05
lb
10.91
kg
Core % of Total Wt.
49%
In Range
45-65%
Total Fuel Weight Burned During Test Run (dry basis)
24.1
lb
10.91
kg
Remainder % of Total Wt.
51%
In Range
35-55%
Actual Load % of Nominal Target
100%
In Range
95-105%
Actual Fuel Load Density
12.0 lb/ft
3
Allowable Charcoal Bed Wt. Range (lb)
3.0
to
5.8
Mid-Point
Actual Charcoal Bed Wt.
3.2 lb
In Range
4.4
Actual Fuel Load Ending Wt.
0.0 lb
Valid Test
≥ 90%
Total Wt. of Fuel Burned During Test Run lb.
29.1 lb
Pc. Wt. Dry Basis
THIS DOCUMENT IS NOT AN ASTM STANDARD; IT IS UNDER CONSIDERATION WITHIN AN ASTM
TECHNICAL COMMITTEE BUT HAS NOT RECEIVED ALL APPROVALS REQUIRED TO BECOME AN ASTM STANDARD.
IT SHALL NOT BE REPRODUCED OR CIRCULATED OR QUOTED, IN WHOLE OR IN PART, OUTSIDE OF ASTM
COMMITTEE ACTIVITIES EXCEPT WITH THE APPROVAL OF THE CHAIRMAN OF THE COMMITTEE HAVING
JURISDICTION AND THE PRESIDENT OF THE SOCIETY.
COPYRIGHT ASTM, 100 BARR HARBOR DRIVE, WEST
5
CONSHOHOCKEN, PA 19428. ALL RIGHTS RESERVED
.
Page 83 of 186
Summary of Contents for Endeavor
Page 22: ...Page 22 of 186 ...
Page 23: ...Page 23 of 186 ...
Page 24: ...Page 24 of 186 ...
Page 34: ...Page 34 of 186 ...
Page 35: ...Page 35 of 186 ...
Page 56: ...Page 56 of 186 ...
Page 57: ...Page 57 of 186 ...
Page 67: ...Page 67 of 186 ...
Page 68: ...Page 68 of 186 ...
Page 91: ...Page 91 of 186 ...
Page 103: ...Page 103 of 186 ...
Page 104: ...Page 104 of 186 ...
Page 108: ...Page 108 of 186 ...
Page 109: ...Page 109 of 186 ...
Page 110: ...Page 110 of 186 ...
Page 111: ...Page 111 of 186 ...
Page 112: ...Page 112 of 186 ...
Page 113: ...Page 113 of 186 ...
Page 114: ...Page 114 of 186 ...
Page 116: ...Page 116 of 186 ...
Page 117: ...Page 117 of 186 ...
Page 118: ...Page 118 of 186 ...
Page 120: ...Page 120 of 186 ...
Page 121: ...Page 121 of 186 ...
Page 122: ...Page 122 of 186 ...
Page 123: ...Page 123 of 186 ...
Page 124: ...Page 124 of 186 ...
Page 127: ...7 20 18 Page 127 of 186 ...
Page 130: ...7 20 18 Page 130 of 186 ...
Page 131: ...Page 131 of 186 ...
Page 133: ...Page 133 of 186 ...
Page 136: ...Page 136 of 186 ...
Page 184: ...34 Optional Equipment Travis Industries 2 25 2019 1507 Endeavor II Listing Label ...