Manufacturer:
Travis Indusstries
Technician Signature:
Model:
Endeavor
Date:
01/09/19
Run:
3
Control #:
0028WS062E
Test Duration:
102
Output Category:
IV
HHV Basis
LHV Basis
Overall Efficiency
73.4%
79.4%
Combustion Efficiency
98.3%
98.3%
Heat Transfer Efficiency
75%
80.8%
Output Rate (kJ/h)
70,725
67,090
(Btu/h)
Burn Rate (kg/h)
4.86
10.72
(lb/h)
Input (kJ/h)
96,326
91,376
(Btu/h)
Test Load Weight (dry kg)
8.27
18.22
dry lb
MC wet (%)
18.11780119
MC dry (%)
22.13
Particulate (g )
#DIV/0!
CO (g)
215
Test Duration (h)
1.70
Emissions
Particulate
CO
g/MJ Output
#DIV/0!
1.79
g/kg Dry Fuel
#DIV/0!
26.01
g/h
#DIV/0!
126.47
lb/MM Btu Output
#DIV/0!
4.16
Air/Fuel Ratio (A/F)
9.16
VERSION:
2.2
12/14/2009
Test Results in Accordance with CSA B415.1-09
Wood Heater Efficiency Results - CSA B415.1
Page 74 of 186
Summary of Contents for Endeavor
Page 22: ...Page 22 of 186 ...
Page 23: ...Page 23 of 186 ...
Page 24: ...Page 24 of 186 ...
Page 34: ...Page 34 of 186 ...
Page 35: ...Page 35 of 186 ...
Page 56: ...Page 56 of 186 ...
Page 57: ...Page 57 of 186 ...
Page 67: ...Page 67 of 186 ...
Page 68: ...Page 68 of 186 ...
Page 91: ...Page 91 of 186 ...
Page 103: ...Page 103 of 186 ...
Page 104: ...Page 104 of 186 ...
Page 108: ...Page 108 of 186 ...
Page 109: ...Page 109 of 186 ...
Page 110: ...Page 110 of 186 ...
Page 111: ...Page 111 of 186 ...
Page 112: ...Page 112 of 186 ...
Page 113: ...Page 113 of 186 ...
Page 114: ...Page 114 of 186 ...
Page 116: ...Page 116 of 186 ...
Page 117: ...Page 117 of 186 ...
Page 118: ...Page 118 of 186 ...
Page 120: ...Page 120 of 186 ...
Page 121: ...Page 121 of 186 ...
Page 122: ...Page 122 of 186 ...
Page 123: ...Page 123 of 186 ...
Page 124: ...Page 124 of 186 ...
Page 127: ...7 20 18 Page 127 of 186 ...
Page 130: ...7 20 18 Page 130 of 186 ...
Page 131: ...Page 131 of 186 ...
Page 133: ...Page 133 of 186 ...
Page 136: ...Page 136 of 186 ...
Page 184: ...34 Optional Equipment Travis Industries 2 25 2019 1507 Endeavor II Listing Label ...