Stove Installation
(for qualified installers only)
13
© Travis Industries
2/1/2019 - 1507
Endeavor II
Alcove Installation Requirements
Whenever the stove is placed in a location where the ceiling height is less than 7' (2134mm) tall, it is
considered an alcove installation. Because of the reduced height, the special installation requirements
listed below must be met.
Chimney connector and chimney must be one of the following types:
AMERI-TEC model DCC with model HS chimney
DURAVENT model DVL with DURATEC or DURA-PLUS chimney
GSW Super Chimney Twenty-One connected directly to appliance
I.C.C. Excel (2100-2 Can.) (103-HT USA) chimney with HP connector
METALFAB model DW connector with TG chimney
OLIVER MACLEOD PROVENT model PV connector with model 3103 chimney
SECURITY model DP connector with SECURITY model ASHT or S2100 chimney
SELKIRK METALBESTOS model DS connector with model SSII chimney
Standard Masonry Chimney with any one of the above listed connectors
NOTE: Reduced clearance connectors may not connect to the flue collar – an appliance adapter may be required.
Alcoves are classified as combustible or non-combustible. Non-combustible alcoves must have walls
and a ceiling that are 3 1/2" (89mm) thick of a non-combustible material (brick, stone, or concrete -
see Figure 7). This non-combustible material must be spaced and ventilated at least 1" (25mm) off of
all combustible materials (walls, ceiling, etc.) to allow air to move around the non-combustible walls
and ceiling. All other alcoves are considered combustible. The clearances below must be met:
Minimum Clearance
(See the
Figure 7
below)
Combustible Alcove
Non‐Combustible Alcove
A
Sidewall to stove
13"
(330mm)
6"
(152mm)
B
Back-wall to stove
4-1/4" (108mm)
2"
(51mm)
D
Connector to sidewall
21-1/2" (546mm)
14-1/2" (368mm)
E
Connector to back-wall
6-1/2" (165mm)
4-1/4" (108mm)
G
Maximum depth of alcove
48”
(1219mm)
48"
(1219mm)
H
Minimum width of alcove
50”
(1270mm)
36"
(914mm)
J
Minimum height of alcove
84”
(2134mm)
6" (152mm) above stove top
Figure 7
Non-combustible alcove
construction (on walls
and ceiling) - see the
explanation above.
Min. 3 1/2"
(89mm) non-
combustible
material
Combustible
materials
1" (25mm)
Min.
Ventilated
air space
Non-combustible
reinforcer
Summary of Contents for Endeavor
Page 22: ...Page 22 of 186 ...
Page 23: ...Page 23 of 186 ...
Page 24: ...Page 24 of 186 ...
Page 34: ...Page 34 of 186 ...
Page 35: ...Page 35 of 186 ...
Page 56: ...Page 56 of 186 ...
Page 57: ...Page 57 of 186 ...
Page 67: ...Page 67 of 186 ...
Page 68: ...Page 68 of 186 ...
Page 91: ...Page 91 of 186 ...
Page 103: ...Page 103 of 186 ...
Page 104: ...Page 104 of 186 ...
Page 108: ...Page 108 of 186 ...
Page 109: ...Page 109 of 186 ...
Page 110: ...Page 110 of 186 ...
Page 111: ...Page 111 of 186 ...
Page 112: ...Page 112 of 186 ...
Page 113: ...Page 113 of 186 ...
Page 114: ...Page 114 of 186 ...
Page 116: ...Page 116 of 186 ...
Page 117: ...Page 117 of 186 ...
Page 118: ...Page 118 of 186 ...
Page 120: ...Page 120 of 186 ...
Page 121: ...Page 121 of 186 ...
Page 122: ...Page 122 of 186 ...
Page 123: ...Page 123 of 186 ...
Page 124: ...Page 124 of 186 ...
Page 127: ...7 20 18 Page 127 of 186 ...
Page 130: ...7 20 18 Page 130 of 186 ...
Page 131: ...Page 131 of 186 ...
Page 133: ...Page 133 of 186 ...
Page 136: ...Page 136 of 186 ...
Page 184: ...34 Optional Equipment Travis Industries 2 25 2019 1507 Endeavor II Listing Label ...