Convection Air Diverter (Front vs. Back)
This fireplace is equipped with an air deflector to allow the heated convection air to be directed to the front, back, or both.
FRONT
Divided Air Flow (stock)
FRONT
Air Flow to Front
Air Flow to Back
FRONT
To adjust the air deflector, remove the glass frame and locate the two 3/4” holes in the firebox ceiling. Use a 7/16”
nutdriver (or socket wrench) to adjust the deflector.
--To adjust the air to the front, adjust the right side diverter clockwise (approximately ¼ turn) and the left side diverter
counter-clockwise.
--To adjust the air to the rear, adjust the right side diverter counter-clockwise (approximately ¼ turn) and the left side
diverter clockwise.
--NOTE: You can adjust the diverter to any combination to obtain the desired heat distribution.
Cutaway of Air Diverter