TransVu Compact
76
Add Still Image
This will record a still image of the trigger along with the standard recording.
This can then be sent on to an external destination.
Email Image
If this option is selected, a JPEG will be added to the reporting email (if Email
Reporting is selected).
Protect alarm Images
Alarm images can automatically be protected from
being overwritten.
Goto Preset
It is possible to action a camera to automatically be sent to a preset position
when an alarm is triggered.
Email Reporting
The unit can send an email when an alarm is detected, refer to ‘Network-E-mail’
for more information.
Alarm Rate Change
Select to change to the alarm mode recording rate on zone action.
VMD/Activity Inhibit
Select to inhibit (ignore) the VMD/Activity detection feature. Refer to ‘Activity
Setup’ for more information.
System Set
Select to change to the ‘Set’ mode recording rate on zone action.
Preset Camera
The preset camera is the camera which will be sent to a designated preset
position upon alarm activation.
Preset
Enter the preset position number for the selected camera here, refer to ‘Unit
Operation-PTZ Program’ for more information on establishing camera preset
positions.
Relay
Select an onboard or external relay to automatically close on receipt of an
alarm.
Relay Duration
Enter (in seconds) how long the relay is to remain closed.
Alarm Image Snapshot Delay This figure allows a delay to be introduced before an alarm snapshot is
taken. This is used when the alarm relates to a PTZ camera which has to travel
to a preset position.
System Overide
Select to change to the ‘Overide’ mode recording rate on
zone action.
Play Audio Message
Following a Zone alarm trigger, a specific audio message
can be played.
IMPORTANT:
Audio messages must be uploaded to the unit in mono 8k wav format only.
The following naming convention must be used: messageXX.wav
i.e. message00.wav, message01.wav etc.
An FTP client should be used to place the wav files in the following folder:
\mdd0\messages folder .