INTRODUCTION

INTRODUCTION

2

3

The signs below might be in the user manual, labeling or other component. 

They are the requirement of standard and using.

Safety Information

Thank you for selecting TRANSTEK arm type blood pressure monitor 

(TMB-1872-B). The monitor features blood pressure measurement, pulse  

rate measurement and the result storage. The design provides you with  

two years of reliable service.

Readings taken by the TMB-1872-B are equivalent to those obtained by a 

trained observer using the cuff and stethoscope auscultation method.

This manual contains important safety and care information, and 

provides step by step instructions for using the product.

Read the manual thoroughly before using the product.

Features:

60*74mm Digital LCD display

 

Maximum 60 records per each user

Measuring during inflation technology

General Description

The Transtek Blood Pressure Monitor is a digital monitor intended for use in 

measuring blood pressure and heartbeat rate with arm circumference ranging 

from  22cm to 32cm(about 8¾˝-12½˝) or 22cm to 42cm(about 8¾˝-16½˝).

It is intended for adult indoor use only.

Indications for Use

Measurement Principle

Contraindications

1.The device should not  be used by any person who may be suspected of,or is  pregnant .

2.The device is not suitable for use on patients with implanted,electrical devices,

such as cardiac pacemakers, defibrillators. 

   This product uses the Oscillometric Measuring method to detect blood pressure. 

Before every measurement, the unit establishes a “zero pressure” equivalent to the 

atmopheric pressure. Then it starts inflating the arm cuff, meanwhile, the unit detects 

pressure oscillations generated by beat-to-beat pulsatile, which is used to determine 

the systolic and diastolic pressure, and also pulse rate.

    

The Green Dot is the license 

symbol of a European 

network of industry-funded

systems for recycling the 

packaging materials of 

consumer goods.

Symbol for “RECYCLE”

Symbol for “THE OPERATION 

GUIDE MUST BE READ”

Symbol for “MANUFACTURER”

Symbol for “SERIAL NUMBER”

Symbol for “TYPE BF APPLIED 

PARTS”

Symbol for “DIRECT CURRENT”

Symbol for “ENVIRONMENT 

PROTECTION - Electrical waste 

products should not be disposed of 

with household waste. Please recycle 

where facilities exist. Check with your 

local authority or retailer for recycling 

advice”

For indoor use only

F1

T1A/250V Φ3.6*10CCC

Symbol for “Class II Equipment”

Caution: These notes must 

be observed to prevent any 

damage to the device.

SN

Symbol for “MANUFACTURE

DATE”

Summary of Contents for TMB-1872-B

Page 1: ...e Monitor TMB 1872 B Please read the user manual carefully and thoroughtly so as to ensure the safe usage of this product Keep the manual well for further reference in case you have problems Guangdong...

Page 2: ...he Records INFORMATION FOR USER 21 Tips for measurement Maintenances ABOUT BLOOD PRESSURE 23 What are systolic pressure and diastolic pressure What is the standard blood pressure classification Irregu...

Page 3: ...rinciple Contraindications 1 The device should not be used by any person who may be suspected of or is pregnant 2 The device is not suitable for use on patients with implanted electrical devices such...

Page 4: ...oes not result in prolonged impairment of patient blood circulation When measurement please avoid compression or restriction of the connection tubing The device cannot be used with HF surgical equipme...

Page 5: ...neously Cleaning Dust environment may affect the performance of the unit Please use the soft cloth to clean the whole unit before and after use Don t use any abrasive or volatile cleaners The device d...

Page 6: ...ies 2 Installing and Replacing the Batteries CAUTION CAUTION Replace the batteries whenever the below happens The shows The display is dim The display does not light up Do not use new and used batteri...

Page 7: ...hen press SET button for 3 seconds to enter the mode for year setting 3 When you get the right year press SET button to set down and turn to next step 4 Repeat steps 2 and 3 to set the MONTH and DAY 5...

Page 8: ...connect with your smartphone on the app to continute the pair up Bluetooth Module No LS8261 RF Frequency Range 2400 MHz to 2483 5 MHz Output Power Range 8dBm Supply Voltage 1 9 3 6 V Transmitting Dist...

Page 9: ...asurements at approximately the same time on the same arm or as directed by a physician 5 6 Take the measurement in a silent room The cuff should maintain at the same level as the right atrium of the...

Page 10: ...mbol will not blink then the device will turn off 1 When the monitor is off press Start Stop button to turn on the monitor and it will finish the whole measurement Adjust the zero LCD display Inflatin...

Page 11: ...ed from the list The corresponding time is 10 38 The corresponding date is 2019 year July 1st CAUTION The date and time of the record will be shown alternately The current No is No 1 three records in...

Page 12: ...smoking When talking or moving your fingers When you want to discharge urine 1 Hold pressing MEM button for 3 seconds when the monitor is in the memory recall mode the flash display dEL ALL User ID w...

Page 13: ...usable cuff with water and never immerse the cuff in water An irregular heartbeat is detected when a heartbeat rhythm varies while the device is measuring systolic pressure and diastolic pressure Duri...

Page 14: ...his section includes a list of error messages and frequently asked questions for problems you may encounter with your blood pressure monitor If the products not operating as you think it should check...

Page 15: ...protection Protection against ingress of water Software Version A01 Pressure 5 C 40 C within 3mmHg 0 4kPa Pulse value 5 Device Classification Battery Powered Mode Internally Powered ME Equipment AC Ad...

Page 16: ...Biological evaluation of medical devices Part 10 Tests for irritation and skin sensitization EN ISO 15223 1 2016 ISO 15223 1 2016 Medical devices Symbols to be used with medical device labels labellin...

Page 17: ...hat supplies buildings used for domestic purposes Guidance and manufacturer s declaration electromagnetic immunity Immunity test 8 kV contact 15 kV air 8 kV contact 15 kV air 2 kV power supply lines l...

Page 18: ...te for the frequency of the transmitter Recommended separation distances d 0 35 d 1 2 10V m 80 Am at 1kHz 80 MHz to 800 MHz d 1 2 800 MHz to 2 7 GHz d 2 3 where P is the maximum output power rating of...

Page 19: ...960 GSM 800 900 TETRA 800 iDEN 820 CDMA 850 LTE Band 5 Pulse modulation b 18Hz 2 0 3 28 1720 1845 1970 1700 1990 GSM 1800 CDMA 1900 GSM 1900 DECT LTE Band 1 3 4 25 UMTS Pulse modulation b 217Hz 2 0 3...

Reviews: