DC Power Consumption
Non Load
Input:
Voltage
Unit
Current
Unit
Power
Unit
12VDC
V
0.387
A
4.644
W
24VDC
0.326
5.664
DC :
Voltage
Unit
Current
Unit
Power
Unit
1.1
V
0.5
A
0.55
W
3.3
0.21
0.963
Full Loading
60W PoE Load:
Input:
Voltage
Unit
Current
Unit
Power
Unit
12VDC
(1)
V
6.67
A
80.4
W
DC:
Voltage
Unit
Current
Unit
Power
Unit
1.1
V
1.34
A
1.474
W
3.3
0.75
2.475
120W PoE Load:
Input:
Voltage
Unit
Current
Unit
Power
Unit
24VDC
(2)
V
6.67
A
160.8
W
24VDC
(2)
2.9
139.2
DC:
Voltage
Unit
Current
Unit
Power
Unit
1.1
V
1.34
A
1.474
W
3.3
0.74
2.442
(1) Using Delta 915w power 12VDC as an input voltage
.
(2) Use EXTECH EAB-140 Programmable AC power supply,
the output must be equipped with high withstand voltage capacitor filtering.