Communications
Ithaca
®
8000
Programmer’s Guide
Page 282
Rev D
100-06908
Flow Chart 2 illustrates how the print control software takes data from the buffer and
controls flow. At the top of the chart, the print control software asks for data. If there is
no data in the buffer, a ―no data flag‖ is returned. The print software must then wait for
data. If there is data in the buffer, it is read, and the pointers are updated. The buffer is
then checked to see how much information is left. If the buffer is below a low watermark
(about 100 bytes left), the communication driver is notified, and DTR is reasserted.
When XON/XOFF flow control is used, the flow is similar to DTR flow except that DTR is
not used and XON/XOFF control characters are transmitted back to the host on the
serial link. The XON/XOFF advantage is that only three wires are required to
interconnect to a printer. The disadvantage is that a serial-port receiver driver must be
written for the host.
Flow Chart 2 Print Controller Using Data
Return data to print
controller.
Is the buffer
below the low
watermark?
No
Set DTR or transmit
XON.
Yes
The print controller needs
data to print or a
command to decode.
Return to print controller
with no data available.
Acquire data from the
buffer.
Is there any
data in the
buffer?
Move buffer pointers to
the next data byte.
Yes
Loop through idle
task, and then look
for more data.
No
Summary of Contents for Ithaca 8000
Page 1: ...Ithaca 8000 Programmer s Guide PN 100 06908 Rev D November 2010...
Page 2: ...This page intentionally left blank...
Page 13: ...100 06908 Rev D Page xi...
Page 14: ......
Page 15: ...100 06908 Rev D Page 1 chapter 1 Introducing your Ithaca 8000 Printer...
Page 16: ...Page 2 Rev D 100 06908 This page intentionally left blank...
Page 22: ......
Page 23: ...100 06908 Rev D Page 9 chapter 2 Ithaca 8000 Specifications and Requirements...
Page 24: ...Page 10 Rev D 100 06908 This page intentionally left blank...
Page 42: ...Page 28 Rev D 100 06908 chapter 3 Setup Procedures...
Page 43: ...100 06908 Rev D Page 29 This page intentionally left blank...
Page 51: ...100 06908 Rev D Page 37 chapter 4 How to Operate the Ithaca 8000 Printer...
Page 52: ...Page 38 Rev D 100 06908 This page intentionally left blank...
Page 60: ......
Page 61: ...100 06908 Rev D Page 47 chapter 5 Configuring Your Ithaca 8000 Printer...
Page 62: ...Page 48 Rev D 100 06908 This page intentionally left blank...
Page 68: ......
Page 69: ...100 06908 Rev D Page 55 chapter 6 Programming Codes...
Page 70: ...Page 56 Rev D 100 06908 This page intentionally left blank...
Page 251: ...100 06908 Rev D Page 237 chapter 7 Ithaca 8000 Color Graphics...
Page 252: ...Page 238 Rev D 100 06908 This page intentionally left blank...
Page 267: ...100 06908 Rev D Page 253 chapter 8 Unicode...
Page 268: ...Page 254 Rev D 100 06908 This page intentionally left blank...
Page 272: ......
Page 273: ...100 06908 Rev D Page 259 chapter 9 Ithaca 8000 Extended Printer Control...
Page 274: ...Page 260 Rev D 100 06908 This page intentionally left blank...
Page 280: ......
Page 281: ...100 06908 Rev D Page 267 chapter 10 Communications...
Page 282: ...Page 268 Rev D 100 06908 This page intentionally left blank...
Page 306: ......
Page 310: ......
Page 312: ......