Programming Codes
Ithaca
®
8000
Programmer’s Guide
100-06908
Rev D
Page 227
Function
Transmit maintenance counter
ASCII
[GS] g 2 m nl nh:
Hexadecimal
1DH 67H 32H
Decimal
<29> <103> <50>
Description
Transmits the value of the specified maintenance counter.
• nl, nh specifies the maintenance counter number as (nl + nh x 256)
Counter number
Counter [Units]
Kind of counter
Hex
Decimal
14
20
Number of line feeds: roll paper
can be reset
14
20
Number of times energizing head: roll paper
14
20
Number of autocutter operations
14
20
Printer operation time
14
20
Number of line feeds: roll paper
cumulative
14
20
Number of times energizing head: roll paper
14
20
Number of autocutter operations
14
20
Printer operation time
• The contents of the maintenance counter are as follows:
Hexadecima
l
Decimal
Amount of data
Header
5FH
95
1 byte
Data
30H-39H
48-57
1-10 bytes
NUL
00H
0
1 byte
• During the transmission of block data values in the maintenance counter, the printer ignores
the real-time command
s.
Also, the printer does not transmit ASB even when the ASB is
enabled. Therefore, the user cannot confirm changes in the printer status during these periods.
• The counter values may be different from the actual counts depending on time differences at
power off or the occurrence of an error.
Summary of Contents for Ithaca 8000
Page 1: ...Ithaca 8000 Programmer s Guide PN 100 06908 Rev D November 2010...
Page 2: ...This page intentionally left blank...
Page 13: ...100 06908 Rev D Page xi...
Page 14: ......
Page 15: ...100 06908 Rev D Page 1 chapter 1 Introducing your Ithaca 8000 Printer...
Page 16: ...Page 2 Rev D 100 06908 This page intentionally left blank...
Page 22: ......
Page 23: ...100 06908 Rev D Page 9 chapter 2 Ithaca 8000 Specifications and Requirements...
Page 24: ...Page 10 Rev D 100 06908 This page intentionally left blank...
Page 42: ...Page 28 Rev D 100 06908 chapter 3 Setup Procedures...
Page 43: ...100 06908 Rev D Page 29 This page intentionally left blank...
Page 51: ...100 06908 Rev D Page 37 chapter 4 How to Operate the Ithaca 8000 Printer...
Page 52: ...Page 38 Rev D 100 06908 This page intentionally left blank...
Page 60: ......
Page 61: ...100 06908 Rev D Page 47 chapter 5 Configuring Your Ithaca 8000 Printer...
Page 62: ...Page 48 Rev D 100 06908 This page intentionally left blank...
Page 68: ......
Page 69: ...100 06908 Rev D Page 55 chapter 6 Programming Codes...
Page 70: ...Page 56 Rev D 100 06908 This page intentionally left blank...
Page 251: ...100 06908 Rev D Page 237 chapter 7 Ithaca 8000 Color Graphics...
Page 252: ...Page 238 Rev D 100 06908 This page intentionally left blank...
Page 267: ...100 06908 Rev D Page 253 chapter 8 Unicode...
Page 268: ...Page 254 Rev D 100 06908 This page intentionally left blank...
Page 272: ......
Page 273: ...100 06908 Rev D Page 259 chapter 9 Ithaca 8000 Extended Printer Control...
Page 274: ...Page 260 Rev D 100 06908 This page intentionally left blank...
Page 280: ......
Page 281: ...100 06908 Rev D Page 267 chapter 10 Communications...
Page 282: ...Page 268 Rev D 100 06908 This page intentionally left blank...
Page 306: ......
Page 310: ......
Page 312: ......