23
Performance
Data
SSP-PRC002-EN
(System)
Table PD-12 — Gross Heating Capacities (MBh)
TWA200B Heat Pump with TWE200B Air Handler At 6675 CFM (I-P)
Outdoor
Heating Capacity (BTUH/1000) At
Total Power in Kilowatts At
Temperature
Indicated Indoor Dry Bulb Temperature
Indicated Indoor Dry Bulb Temperature
(°F)
60
70
75
80
60
70
75
80
-18
42.4
79.1
84.7
87.4
11.5
15.4
16.6
17.6
-13
68.2
86.2
90.2
92.3
13.0
15.6
16.7
17.7
-8
81.5
93.8
96.7
98.0
13.6
15.9
16.9
17.9
-3
93.1
101.8
103.7
104.5
14.1
16.2
17.1
18.1
2
104.2
110.2
111.4
111.7
14.5
16.4
17.4
18.3
7
115.2
119.2
119.8
119.7
14.9
16.7
17.6
18.6
12
126.6
128.8
128.9
128.5
15.2
17.0
17.9
18.9
17
138.2
139.1
138.8
138.2
15.5
17.3
18.2
19.2
22
150.3
150.1
149.5
148.6
15.9
17.6
18.6
19.6
27
162.9
161.8
160.9
159.8
16.2
18.0
18.9
20.0
32
176.1
174.3
173.2
171.9
16.5
18.3
19.3
20.4
37
189.2
186.9
185.6
184.3
16.9
18.7
19.7
20.8
42
202.8
200.0
198.6
197.2
17.2
19.1
20.2
21.3
47
216.9
213.8
212.3
210.8
17.6
19.5
20.6
21.8
52
231.9
228.5
226.8
225.3
18.0
20.0
21.1
22.3
57
247.4
243.6
241.9
240.3
18.4
20.5
21.7
22.9
62
263.2
259.1
257.2
255.6
18.9
21.0
22.2
23.5
67
279.3
274.8
272.8
271.0
19.4
21.6
22.8
24.1
72
295.9
291.1
289.0
287.0
20.0
22.2
23.4
24.7
Table PD-12 — Gross Heating Capacities (kW)
TWA200B Heat Pump with TWE200B Air Handler At 11340 m
3
/h (SI)
Outdoor
Heating Capacity (kW) At
Total Power in Kilowatts At
Temperature
Indicated Indoor Dry Bulb Temperature
Indicated Indoor Dry Bulb Temperature
(°C)
15.6
21.1
23.9
26.7
15.6
21.1
23.9
26.7
-27.8
12.4
23.2
24.8
25.6
5.5
6.0
6.2
6.5
-25.0
20.0
25.3
26.4
27.0
5.6
6.1
6.3
6.6
-22.2
23.9
27.5
28.3
28.7
5.7
6.2
6.5
6.7
-19.4
27.2
29.8
30.4
30.6
5.8
6.3
6.6
6.9
-16.7
30.5
32.3
32.6
32.7
5.9
6.5
6.7
7.0
-13.9
33.7
34.9
35.1
35.1
6.0
6.6
6.9
7.2
-11.1
37.1
37.7
37.8
37.6
6.2
6.7
7.0
7.4
-8.3
40.5
40.7
40.7
40.5
6.3
6.9
7.2
7.5
-5.6
44.0
43.9
43.8
43.5
6.5
7.0
7.4
7.7
-2.8
47.7
47.4
47.1
46.8
6.6
7.2
7.5
7.9
0.0
51.6
51.0
50.7
50.3
6.8
7.4
7.7
8.1
2.8
55.4
54.7
54.3
54.0
6.9
7.6
7.9
8.3
5.6
59.4
58.6
58.1
57.7
7.1
7.8
8.1
8.5
8.3
63.5
62.6
62.2
61.7
7.3
8.0
8.4
8.8
11.1
67.9
66.9
66.4
66.0
7.5
8.2
8.6
9.0
13.9
72.4
71.3
70.8
70.3
7.7
8.4
8.8
9.2
16.7
77.1
75.9
75.3
74.8
7.9
8.7
9.1
9.5
19.4
81.8
80.5
79.9
79.4
8.1
8.9
9.3
9.8
22.2
86.6
85.2
84.6
84.0
8.4
9.2
9.6
10.0
Correction Factors - Other Airflows
(Table Value x Correction Factor = Value at new airflow)
Airflow
6000 cfm
7325 cfm
10194 m
3
/h
12445 m
3
/h
Heating Capacity
x 0.99
x 1.01
Compressor kW
x 1.02
x 0.98
Values at ARI Rating Conditions of:
70F (21.1C) and 47/43F (8.3/6.1C)(High Temp.Cond.)
70F (21.1C) and 17/15F (-8.3/-9.4C)(Low Temp. Cond)
Airflow = 6700 cfm (11383 m
3
/h)
Heating Capacity (High Temp.) = 214,000 (62.66)
Heating Capacity (Low Temp.) = 139,000 (40.70)
Compressor Power (High Temp) = 15.83 kW
Compressor Power (Low Temp) = 13.50 kW
Coeff. Of Perf. (High Temp) = 3.2
Coeff. Of Perf. (Low Temp) = 2.3
Outdoor Fan Power = 1,200 watts
Indoor Fan Power = 2,300 watts
Note:
1. Rated with 25 feet of 1-3/8” suction and 1/2" liquid line."