10
SSP-PRC002-EN
General
Data
(Heat Pumps)
Table GD-2
General Data — Heat Pumps
TWA155B
TWA200B
Cooling Performance
1
Gross Cooling Capacity, Btu (kW)
Matched Air Handler, Btu (kW)
167,000 (48.9)
218,000 (63.83)
Condensing Unit Only
2
, Btu (kW)
167,000 (48.9)
218,000 (63.83)
ARI Net Cooling Capacity
3
162,000 (47.43)
211,000 (61.78)
System Power kW
15.67
21.51
Condensing Unit Power kW
13.91
19.1
Heating Performance
ARI Heating with Matched Air Handler
High Temperature Capacity, Btu (kW)
166,000 (48.6)
214,000 (62.66)
Low Temperature Capacity, Btu (kW)
101,000 (29.57)
139,000 (40.70)
Compressor
Number
2
2
Type
3D
®
Scroll
3D
®
Scroll
No. Motors
2
2
Motor HP
6.25 (4.7)
8.33 (6.21)
Motor RPM, (kW)
2875
2875
ARI Sound Rating (Bels)
4
8.8
8.8
System Data
5
No. Refrigerant Circuits
2
2
Suction Line, in. (mm) OD
1.375 (34.9)
1.375 (34.9)
Liquid Line, in. (mm) OD
0.500 (12.7)
0.500 (12.7)
Outdoor Coil — Type
Plate Fin
Plate Fin
Tube Size, in. (mm) OD
0.375 (9.5)
0.375 (9.5)
Face Area, sq. ft (m
2
)
38.4 (3.57)
48 (4.46)
Rows
2
2
Fins Per Inch
18
18
Outdoor Fan Type
Propeller
Propeller
No. Used
2
2
Diameter, in. (mm)
26.00 (660.4)
28.00 (711)
Drive Type
Direct
Direct
No. Speeds
1
1
CFM
6
, (m
3
/h)
9800 (16650.2)
13400 (22766.60)
No. Motors
2
2
Motor HP (kW)
0.33 (.25)
0.75 (.56)
Motor RPM
925
925
R-22 Refrigerant Charge, lb
7
(kg)
36.0 (16.33)
48.5 (22.0)
Notes:
1. Cooling Performance is rated at 95°F (35°C) ambient, 80°F (26.7°C) entering dry bulb, 67°F (19.4°C) entering wet
bulb and nominal cfm listed. ARI rating cfm is 350 cfm/ton for this product. Gross capacity does not include the
effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Units are suitable for
operation to ±20% of nominal cfm. Rated accordance with ARI Standard 340/360-00.
2. Condensing Unit Only Gross Cooling Capacity rated at 45°F (7.6°C) saturated suction temperature and at 95°F
(35°C) ambient.
3. ARI Net Cooling Capacity is calculated with matched blower coil and 25 ft (7.6 m) of 1.375, 0.500 OD interconnect-
ing tubing. EER and/or SEER are rated at ARI conditions and in accordance with DOE test procedures. Integrated
Part Load Value is based on ARI Standard 340/360-00. Units are rated at 80°F (26.7°C) ambient, 80°F (26.7°C) entering dry
bulb, and 67°F (19.4°C) entering wet bulb at ARI rated cfm.
4. ARI Sound Rating is rated in accordance with ARI Standard 270 or 370.
5. System Data based on maximum linear length 80 ft (26.7 m)Maximum lift: suction 60 ft (18.3 m) liquid 60 ft (18.3
m) For greater lengths, refer to refrigerant piping applications manual.
6. Outdoor Fan cfm is rated with standard air-dry coil outdoor.
7. Refrigerant (operating) charge is for condensing unit (all circuits) with matching blower coils and 25 ft (7.6 m) of
interconnecting refrigerant lines.
Summary of Contents for TWE050A
Page 35: ...35 SSP PRC002 EN Typical Wiring Heat Pump...
Page 37: ...37 SSP PRC002 EN Typical Wiring Heat Pump...
Page 54: ......
Page 55: ......