13
Performance
Data
SSP-PRC002-EN
(System)
Table PD-2 — Gross Cooling Capacities (MBh) TWA100A Heat Pump with TWE100A Air Handler (I-P)
Ambient Temperature (°F)
85
95
105
115
Enter.
Dry
Entering Wet Bulb (°F)
Bulb
61
67
73
61
67
73
61
67
73
61
67
73
CFM
(°F)
Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens.
3000
75
103.1
81.2 113.7 68.1 125.2 46.1
99.3
79.2 109.5 66.4 120.5 44.4 95.2 77.2 105.1 64.6 115.7 42.7 91.0 75.1 100.5 62.7 110.6 41.0
80
103.4 94.5 113.9 77.5 125.1 59.9
99.7
92.6 109.7 75.6 120.5 58.2 95.8 90.6 105.3 73.7 115.7 56.3 91.7 88.5 100.7 71.8 110.6 54.4
85
105.4 105.4 113.9 90.8 125.2 73.3
102.2 102.2 109.7 88.8 120.6 71.5 98.9 98.9 105.4 86.8 115.8 69.7 95.3 95.3 100.8 84.8 110.8 67.8
90
110.6 110.6 114.3 103.9 125.3 86.6
107.3 107.3 110.2 102.0 120.7 84.8 103.8 103.8 106.0 100.1 115.9 83.0 100.2 100.2 101.6 98.1 110.9 81.1
3325
75
105.0 84.7 115.8 66.1 127.2 46.9
101.1
82.8 111.4 64.3 122.4 45.3 96.9 80.7 106.9 62.4 117.4 43.5 92.5 78.5 102.2 60.4 112.2 41.6
80
105.6 99.3 115.9 80.8 127.1 61.8
101.8
97.4 111.6 78.9 122.4 60.0 97.8 95.3 107.0 77.0 117.4 58.1 93.7 93.3 102.3 75.1 112.2 56.2
85
108.7 108.7 115.9 95.1 127.2 76.3
105.4 105.4 111.6 93.2 122.5 74.5 101.9 101.9 107.1 91.1 117.5 72.6 98.2 98.2 102.5 89.1 112.4 70.7
90
114.1 114.1 116.6 109.5 127.3 90.7
110.6 110.6 112.5 107.6 122.6 88.9 107.0 107.0 108.2 105.6 117.7 87.1 103.2 103.2 103.8 103.7 112.4 84.9
3650
75
106.6 88.1 117.4 68.2 128.8 47.8
102.6 86.1 113.0 66.3 123.9 46.0 98.3 84.0 108.3 64.4 118.8 44.1 93.9 81.9 103.5 62.4 113.4 42.2
80
107.6 103.9 117.6 84.0 128.8 63.5
103.7 102.0 113.1 82.1 123.9 61.7 99.1 99.1 108.5 80.2 118.8 59.8 95.4 95.4 103.6 77.9 113.5 57.9
85
111.6
111.6 117.6 99.3 128.9 79.1
108.1 108.1 113.2 97.3 124.1 77.3 104.5 104.5 108.7 95.3 119.0 75.5 100.6 100.6 104.0 93.2 113.7 73.5
90
117.1
117.1 118.7 114.9 129.0 94.7
113.5 113.5 114.5 113.0 124.2 92.9 109.8 109.8 109.7 109.7 119.0 90.7 105.8 105.8 105.7 105.7 113.8 88.6
3975
75
108.1
91.4 118.9 70.1 130.2 48.3
103.9 89.3 114.3 68.3 125.2 46.5 99.6 87.2 109.6 66.3 120.0 44.7 95.1 85.1 104.6 64.3 114.5 42.8
80
109.4 108.4 119.0 87.0 130.3 65.2
105.0 105.0 114.4 84.9 125.3 63.3 101.3 101.3 109.7 82.9 120.1 61.5
97.5
97.5 104.7 80.8 114.7 59.5
85
114.2 114.2 119.1 103.3 130.4 81.9
110.6 110.6 114.7 101.3 125.4 80.1 106.8 106.8 110.1 99.3 120.2 78.2 102.8 102.8 105.3 97.2 114.8 76.2
90
119.9 119.9 120.7 120.2 130.4 98.3
116.2 116.2 116.1 116.1 125.4 96.3 112.2 112.2 112.2 112.2 120.3 94.3 108.1 108.1 108.1 108.1 114.9 92.3
Note: All temperatures are in degrees Fahrenheit. Airflow is in cfm.
Table PD-2 — Gross Cooling Capacities (kW) TWA100A Heat Pump with TWE100A Air Handler (SI)
Ambient Temperature (°C)
29.4
35.0
40.6
46.1
Enter.
Dry
Entering Wet Bulb (°C)
Bulb
16.1
19.4
22.8
16.1
19.4
22.8
16.1
19.4
22.8
16.1
19.4
22.8
m
3
/h
(°C)
Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens.
5097
24
30.2
23.8 33.3 19.9 36.6 13.5
29.1
23.2 32.1 19.4 35.3 13.0 27.9 22.6 30.8 18.9 33.9 12.5 26.6 22.0 29.4 18.4 32.4 12.0
27
30.3
27.7 33.3 22.7 36.6 17.5
29.2
27.1 32.1 22.1 35.3 17.0 28.0 26.5 30.8 21.6 33.9 16.5 26.9 25.9 29.5 21.0 32.4 15.9
29
30.9
30.9 33.3 26.6 36.7 21.5
29.9
29.9 32.1 26.0 35.3 20.9 28.9 28.9 30.8 25.4 33.9 20.4 27.9
27.9 29.5 24.8 32.4 19.8
32
32.4
32.4 33.5 30.4 36.7 25.4
31.4
31.4 32.3 29.9 35.3 24.8 30.4 30.4 31.0 29.3 33.9 24.3 29.3 29.3 29.8 28.7 32.5 23.7
5649
24
30.7
24.8 33.9 19.4 37.2 13.7
29.6
24.2 32.6 18.8 35.8 13.3 28.4 23.6 31.3 18.3 34.4 12.8 27.1 23.0 29.9 17.7 32.8 12.2
27
30.9
29.1 33.9 23.7 37.2 18.1
29.8
28.5 32.7 23.1 35.8 17.6 28.6 27.9 31.3 22.6 34.4 17.0
27.4
27.3 30.0 22.0 32.9 16.5
29
31.8
31.8 33.9 27.8
37.3 22.3
30.9
30.9 32.7 27.3 35.9 21.8 29.8 29.8 31.4 26.7 34.4 21.3 28.7 28.7 30.0 26.1 32.9 20.7
32
33.4
33.4 34.1 32.1 37.3 26.6
32.4
32.4 32.9 31.5 35.9 26.0 31.3 31.3 31.7 30.9 34.4 25.5 30.2 30.2 30.4 30.3 32.9 24.8
6201
24
31.2
25.8 34.4 20.0 37.7 14.0
30.0
25.2 33.1 19.4 36.3 13.5 28.8 24.6 31.7 18.9 34.8 12.9 27.5 24.0 30.3 18.3 33.2 12.4
27
31.5
30.4 34.4 24.6 37.7 18.6
30.4
29.9 33.1 24.0 36.3 18.1 29.0 29.0 31.8 23.5 34.8 17.5
27.9
27.9 30.3 22.8 33.2 17.0
29
32.7
32.7 34.4 29.1 37.8 23.2
31.7
31.7 33.2 28.5 36.3 22.6 30.6 30.6 31.8 27.9 34.8 22.1 29.5 29.5 30.4 27.3 33.3 21.5
32
34.3
34.3 34.8 33.7 37.8
27.7
33.2
33.2 33.5 33.1 36.4 27.2 32.1 32.1 32.1 32.1 34.8 26.5 31.0 31.0 31.0 31.0 33.3 25.9
6754
24
31.6
26.7 34.8 20.5 38.1 14.2
30.4
26.2 33.5 20.0 36.7 13.6 29.2 25.5 32.1 19.4 35.1 13.1 27.8 24.9 30.6 18.8 33.5 12.5
27
32.0
31.7 34.8 25.5 38.1 19.1
30.8
30.8 33.5 24.9 36.7 18.5 29.7 29.7 32.1 24.3 35.2 18.0 28.5 28.5 30.7 23.7 33.6 17.4
29
33.4
33.4 34.9 30.2 38.2 24.0
32.4
32.4 33.6 29.7 36.7 23.4 31.3 31.3 32.2 29.1 35.2 22.9 30.1 30.1 30.8 28.5 33.6 22.3
32
35.1
35.1 35.3 35.2 38.2 28.8
34.0
34.0 34.0 34.0 36.7 28.2 32.9 32.9 32.8 32.8 35.2 27.6 31.7 31.7 31.6 31.6 33.6 27.0
Note: All temperatures are in degrees Celsius. Airflow is in liters per second.