Selecting Temporary Occupancy (Timed Override)
Temporary occupancy (timed override) is available on some sensors. Temporary occupancy can be
selected to adjust temperature, fan, or heat/cool settings after the system has changed to
unoccupied mode. System control will revert to unoccupied after a pre-determined time period.
Note:
Not all systems support the occupancy function.
Sensors with Occupied/Unoccupied buttons
To select temporary occupancy, press the Occupied button (
) for 0.2–6 seconds. The
following occurs:
•
Space temperature output is driven to 10
(nominal).
•
The output generates for 4 seconds.
To cancel temporary occupancy, press the Unoccupied button (
) for 0.2–6 seconds. The
following occurs:
•
Space temperature output is driven to 1330
(nominal).
•
The output generates for 4 seconds.
Figure 2. Locations of Occupied button and Unoccupied buttons
Display Sensors
To select and cancel temporary occupancy, see
“Requesting Temporary Occupancy,” p. 31
.
Occupied button
Unoccupied button