earthing wire resistance measured by any PEC-01 unit exceeds the limit provided,
or if there is a break in the wire. The alarm is deactivated and the LED is on
steadily when all the above-mentioned values have returned to 5% below the
alarm limit. The alarm limit is set in the SETUP menu.
The SYSTEM FAULT LED blinks if the system has not received a command from
the IM-01.MED unit within three seconds. The screen also goes into System Fault
mode. The alarm is deactivated if the connection is restored. The error is always
unit-specific; in other words, it is only displayed in the affected unit. In the IM-
01.MED unit, the error is displayed as a REMOTE UNITS error.
The MON/ALARM button changes the screen mode between monitor and alarm
modes.
The MUTE ALARM button silences the audible alarm. It does not have any other
effect on the functioning of the system as a whole.
A short press of the
button changes the value displayed on the bottom line of
the display. A long press of the button (5 s) gives the IM-01.MED unit the
command to perform a system test.
The RD-01 unit has two screen modes: monitor and alarm. In addition, the system test
mode and setup mode are accessed through the monitor mode.
Monitor mode
In the monitor mode, the unit always displays the insulation resistance value on the
upper line. Additionally, it displays the transformer load current, transformer
temperature or insulation capacitance on the lower line. The value displayed on the
lower line can be changed by shortly pressing the
button.
R 472k
Ω
I 44%
R 472k
Ω
t 30 °C
R 472k
Ω
C 0.2uF
Summary of Contents for SUPERINTEND IC-01
Page 21: ...Superintend IMD Copyright Muuntosähkö Oy Trafox 21 http www trafox fi ...
Page 23: ...Superintend IMD Copyright Muuntosähkö Oy Trafox 23 http www trafox fi ...
Page 28: ...28 Copyright Muuntosähkö Oy Trafox Superintend IMD http www trafox fi ...
Page 35: ...Superintend IMD Copyright Muuntosähkö Oy Trafox 35 http www trafox fi ...
Page 37: ...Superintend IMD Copyright Muuntosähkö Oy Trafox 37 http www trafox fi ...
Page 70: ...70 Copyright Muuntosähkö Oy Trafox Superintend IMD http www trafox fi 36 3 mm 110 mm 62 mm ...