Installation Manual | V1.0.0 | 25
Appendix 1 - Matching of RT sensor signals
TrackWeight load cell (RT sensor) color and description:
Colour of wire
Red
Black
White
Green
Position
1
2
3
4
Name
ALIM (+)
GND (-)
Signal (-)
Signal (+)
The TrackWeight scale adjusts the ALIM voltage to +10.0 VDC relative to the GND, which
matches the recommended value.
The adjustment and operating voltage is read between the green and white wires.