Troubleshooting and diagnosis options
TR-Electronic GmbH 2020, All Rights Reserved
Printed in the Federal Republic of Germany
Page 84 of 88
TR - ELE - BA - DGB - 0030 - 01
06/15/2020
Continuation Event Codes
0x5000
0x04
E
Device hardware fault
See bit 2
0x8C20
0x01
E
Measurement range
over-run
See bit 7
W: WARNING
E: ERROR
9.5 Diag. Operating Hours (Index 0x007A)
This parameter contains the time in [hrs] in which the measuring system was supplied with power.
Index
Subindex
Name
Length
Type
Access
0x007A
0
Diag Operating Hours
32 Bit
UIntegerT
ro