Index 0x0047: Resolution
7.3.2
The parameter
Resolution
defines the measuring system resolution.
Index
Subindex
Name
Length
Type
Access
0x0047
0
Resolution
8 Bit
UIntegerT
rw
Value
Assignment
Description
Default
0x00
10 mm
1 Digit = 1 centimeter
0x01
1 mm
1 Digit = 1 millimeter
X
0x02
1/10 mm
1 Digit = 1/10 millimeter
0x03
1/100 mm
1 Digit = 1/100 millimeter
0x04
1/10 Inch
1 Digit = 1/10 inch
0x05
1 Inch
1 Digit = 1 Inch
0x06
1/8 mm
1 Digit = 1/8 millimeter
0x07
Free Resolution
1 Digit = 1/100 millimeter
Index 0x0048: Free Resolution
7.3.3
The parameter
Free Resolution
defines the measuring system resolution, if under parameter
Resolution
the option
Free resolution
was selected. Input in 1/100 mm.
Index
Subindex
Name
Length
Type
Access
0x0048
0
Free Resolution
16 Bit
UIntegerT
rw
Lower limit
1
Upper limit
65535
Default
100
(1 mm)
Index 0x004A: Dynamic Position Range
7.3.4
Dynamic Position Range
is a parameter, who characterizes mathematic calculation of the
measure-value. With high measuring-dynamic there is no mathematic calculation on the measure-
value, but the noise of the measure-value is larger, in case of small measuring-dynamic the noise is
lower, but there exist a small time-delay for the measure-value.
Index
Subindex
Name
Length
Type
Access
0x004A
0
Dynamic Position
Range
8 Bit
UIntegerT
rw
Value
Assignment
Description
Default
0x00
High
High measuring dynamic
0x01
Medium
Average measuring dynamic
X
0x02
Low
Low measuring dynamic
0x03
No Moving Average
Output of the raw value