Supported Event Codes
EventCode
Device status
(Index 0x0024)
Type Error message
Cause / Remedy
0x1800
0x04
E
High priority error
Check installation for interfering
sources (e.g. vibration,
temperature, strong magnetic
fields.
0x1801
0x04
W
Memory fault
Restart system, try writing
parameter again.
0x1802
0x02
W
Preset value out of
range
Check manual for permitted values
for preset. Check, if preset value
within the measuring range.
0x1803
0x02
E
Driver current limit
exceeded (100mA)
Check installation for short circuit
on DI/DO or C/Q line.
0x1804
0x02
E
Driver enters thermal
shutdown
Check power consumption of the
system and clear external sources
of heat.
0x1805
0x02
W
Position Warning
Check bits of PDin 2^0 'Error
Status' and their meaning in the
manual.
See bit 6
“Other faults”, page 87
0x1806
0x01
W
Intensity Warning
Check bits of PDin 2^0 'Error
Status' and their meaning in the
manual.
See bit 0/4
“Other faults”, page 87
0x1807
0x02
W
Temperature limits
exceeded
Check manual for temperature
limits.
See bit 1
0x1808
0x02
W
Max. Speed exceeded
Configured value of Maximum
Speed (Index 84) has been
exceeded.
See bit 5
Continuation, see following page