![TR-Electronic LE-200 User Manual Download Page 35](http://html.mh-extra.com/html/tr-electronic/le-200/le-200_user-manual_1146676035.webp)
Appendix
Printed in the Federal Republic of Germany
©
TR-Electronic GmbH 2007, All Rights Reserved
14.12.2007
TR - ELE - BA - GB - 0008 - 06
Page 35 of 37
9 Appendix
9.1 Specifications
Note
The electric characteristics have validity, only after an operating time of approximate 30 minutes.
9.1.1 Electrical ratings
Measuring principle: .........................................
Phase delay time measurement
Range (measurement on reflecting foil):........
0,2 – 125 m standard,
170m, 195m, 240m (special devices)
Resolution: ........................................................
selectable, physical resolution 0,7 mm
Linearization
up to 12m (standard):.......................... absolute linearity error
±
3 mm
complete measuring length:................ absolute linearity error
±
5 mm
Operating voltage
Standard device: ................................. 18-27 V DC (
±
5%)
Device with heating: ............................ 24 V DC (
±
5%)
Power consumption (no-load):........................
< 6 watts
Power consumption with heating: ..................
< 60 watts
Opto-transmitter:...............................................
Laser diode (red light)
Wavelength
λ
: ................................... 670 nm
Max. laser power:.............................. P
≤
1 mW
Laser protection class: ...................... 2 according to DIN EN 60 825-1: 2003-10
Lifetime:............................................. 50 000 h
Measured value output / refresh cycle: ..........
1000 values / s
Integration time: ................................................
1 ms
Reproducibility:.................................................
±
2 mm
Programming via RS485:..................................
PC IBM compatible (TRWinProg) / Interbus-S
Interbus-S Interface: .........................................
Interbus-S according to DIN 19258
Two-wire remote bus for transmission and receive
direction, RS422 with galvanic isolation
Profile: ................................................. K3
Ident-No.: ............................................ 55 dec.
Number of words:................................ 2 IN / 2 OUT
Baud rate (programmable):................. 300 kbps net, 500 kbps gross or 2Mbaud
(including control and status bytes)
Data refresh: ....................................... 0,5 ms
Output code:........................................ Binary
Special features: ................................. Programming of the following parameters via the
Interbus-S:
-
Resolution
-
Switch off or switch on laser diode, automatic
-
Preset preselection
-
Counting direction
-
Speed limit value
-
Error value
-
Programming of the ext. switching input/output
-
Clearing zero mark
Switching input / Switching output:................
programmable
Levels switching input: ........................ -level > +8V, 0-level < +2V, up to ±35V, 5 kOhm
Levels switching output:...................... 1-level > US-2V, 0-level < 1 V, up to 100mA
i