Commissioning / Installation
©
TR-Electronic GmbH 2007, All Rights Reserved
Printed in the Federal Republic of Germany
Page 24 of 37
TR - ELE - BA - GB - 0008 - 06
14.12.2007
5.3.3 Status Word (IN-data relative to the master)
Information concerning the state of the laser and messages are shown in the status
word.
Status Word, relative word address "0"
Bit Name
Mandatory
Bit-No. in PD-Channel
0 Reserved
16
1 Reserved
17
2 Reserved
18
3 Reserved
19
4 Reserved
20
5 Reserved
21
6 Reserved
22
7 Reserved
23
8 Reserved
24
9 Parameter no. or malfunction code
X
25
10 Parameter no. or malfunction code
X
26
11 Parameter no. or malfunction code
X
27
12 Parameter no. or malfunction code
X
28
13 Manufacturer-specific
29
14 Parameterization
X
30
15 Invalid position actual value
X
31
Device States
The device states are shown in the status word by the following bit combinations:
Status Word (bit)
Invalid
position
actual
value
Parameteri
zation
Manufac-
turer
specific
Parameter-No.
STATE
15 14 13 12 11 10 9
OPERATION 0
0
X
0
PARAMETERIZATION
1
1
X
1 . . . 15
MALFUNCTION
1
0
X
1 . . . 15