Commissioning / Installation
Printed in the Federal Republic of Germany
©
TR-Electronic GmbH 2007, All Rights Reserved
14.12.2007
TR - ELE - BA - GB - 0008 - 06
Page 23 of 37
Parameter-No.
The bits 9 to 12 (D25 - D28) indicate the number of the parameter at the laser (see
also "Parameter data", page 26). The parameter data will transfer via the bits 0 to 24
of the process out data channel. The activation of parameter transfer is receipted
within a second in the status word.
Set zero shift
If in parameter-no. 1101 is programmed the value "0 = not clear", an edge change of
"0" to "1" of the bit-no. 30 in the process out data channel is setting the laser to the
preselected value in parameter-no. 0100 (see also "Parameter overview", page 26).
Manufacturer-Specific
Bits 0 - 8 are reserved. Bit 13 is manufacturer-specific.