Commissioning / Installation
©
TR-Electronic GmbH 2007, All Rights Reserved
Printed in the Federal Republic of Germany
Page 22 of 37
TR - ELE - BA - GB - 0008 - 06
14.12.2007
5.3.2 Control Word (OUT-data relative to the master)
Via the control word functions activated and the operational states of the laser are
defined.
Control Word, relative word address "0"
Bit
Name
mandatory
Bit-Nr. im PD-Kanal
0 Reserved
16
1 Reserved
17
2 Reserved
18
3 Reserved
19
4 Reserved
20
5 Reserved
21
6 Reserved
22
7 Reserved
23
8 Reserved
24
9 Parameter
no.
X
25
10 Parameter
no.
X
26
11 Parameter
no.
X
27
12 Parameter
no.
X
28
13 Manufacturer-specific
29
14
* Set zero shift
X
30
15 Enable
operation
X
31
* see page 23, "Set zero shift"
Device Control Commands
The device control commands are triggered by the following bit combinations in the
control word:
Control Word (bit)
Enable
operation
Set zero
shift
Manufac-
turer-
specific
Parameter-No.
DEVICE CONTROL
COMMAND
15 14 13 12 11 10 9
ENABLE OPERATION
0>1
0
X
0
PARAMETERIZATION
0
0
X
1 . . . 15