Continuation parameter overview
Parameter No.
B12 B9
Function
1 1 0 0
Function external input:
0 = disabled
1 = Preset
2 = Switch off laser diode
3 = Failure quit
1 1 0 1
Clear preset (Zero mark is deleted):
0 = no clearing
1 = clearing
1 1 1 0
Function external output:
0 = disabled
1 = Temperature
2 = Intensity
3 = Hardware-Fail
4 = every fail
5 = Speed-check
6 = Plausibility measured value
1 1 1 1
Save parameters, D0 – D24 = "0"
The laser switches over to the "parameterization" state and indicates the successful
transmission of the parameter with the return of the corresponding parameter number.
The new parameter takes effect after the user has set the laser to the ’operation’ state
with the ’enable operation’ device control command. If it was not possible for the
parameter to take effect, the laser switches over to the ’malfunction’ state –after the
user has sent the ’enable operation’ device control command - and outputs a
malfunction number on bits 9 to 12 of the status word (bit 25 to 28 of the process data
channel).
Malfunction code
Malfunction-No.
b12 b9
Meaning
0 0 0 0 No
malfunction
0 0 0 1
Invalid parameters from the host
0 0 1 1 Hardware
error
1 0 0 1
Intensity warning (intensity <12%)
1 0 1 0 Laser
diode is switched off
1 1 0 0
Intensity error (e.g. beam interruption)
1 1 0 1 Speed-check
1 1 1 0
Device temperature (outside the range of 0-50 °C)
1 1 1 1 Plausibility measured value (position jump)