6.2 Parameter description
The range of values of parameter data in D0 - D24 is to be entered in two's
complement. In the case of a value limit error, after the device control command
"enable operation" the laser is switching over to the "malfunction" state, no
programming occurs.
(e.g. +1 dec.: Parameter data = 1 HEX
-1 dec.: Parameter data = 1 FF FF FF HEX)
6.2.1 Resolution
Determination of the measuring system resolution
Parameter-No.
B12 B9
Parameter value in
D0 - D24
Value range
Default
0 0 0 1
0 = 10 mm
1 = 1 mm
2 = 0,1 mm
3 = 0,01 mm
4 = 1 Inch
5 = 0,1 Inch
0 - 5
1
6.2.2 Switching-off laser diode
For increase the life time of the laser diode the laser diode can be switched inactively
with transmission of this parameter-no.. If in parameter-no. 1100 "Function external
input", page 32 the parameter value "2" = "Switch off laser diode" was programmed,
or the parameter 0101 "Switch off laser diode automatic if Interbus-S is inactive",
page 31 is active, this parameter is ineffective.
Parameter-No.
B12 B9
Parameter value in
D0 - D24
Value range
Default
0 0 1 0
-
- -
6.2.3 Switching-on laser diode
With transmission of this parameter-no. the laser diode is switched actively. If in
parameter-no. 1100 "Function external input", page 32 the parameter value "2" =
"Switch off laser diode" was programmed, or the parameter 0101 "Switch off laser
diode automatic if Interbus-S is inactive", page 31 is active, this parameter is
ineffective.
Parameter-No.
B12 B9
Parameter value in
D0 - D24
Value range
Default
0 0 1 1
-
- -