7.2.2 Extended diagnosis
In addition to the standard DP diagnostic message, the measuring system also
provides an extended diagnostic message according to the PNO measuring system
profile. This message varies in length depending on the chosen nominal configuration.
In the configurations designated "TR-mode", the diagnostic message corresponds to
PNO Class 2.
The following pages provide a general overview of the available diagnostic
information. Which individual options your measuring system actually supports can be
read out from the device itself.
Byte no.
Meaning
Class
E
x
te
nd
e
d
di
a
gnos
is
Byte 7
Length (in bytes) of extended diagnosis
1/2/TR
Byte 8
Alarms
1/2/TR
Byte 9
Operating status
1/2/TR
Byte 10
Encoder type
1/2/TR
Byte 11-14
Encoder resolution in increments per revolution (rotary)
Encoder resolution in measuring increments (linear)
1/2/TR
Byte 15-16
Number of resolvable revolutions
1/2/TR
Byte 17
Additional alarms
2/TR
Byte 18-19
Supported alarms
2/TR
Byte 20-21
Warnings
2/TR
Byte 22-23
Supported warnings
2/TR
Byte 24-25
Profile version
2/TR
Byte 26-27
Software version (firmware)
2/TR
Byte 28-31
Operating hour counter
2/TR
Byte 32-35
Offset value
2/TR
Byte 36-39
Manufacturer's offset value
2/TR
Byte 40-43
Number of increments per revolution
2/TR
Byte 44-47
Measuring length in increments
2/TR
Byte 48-57
Serial number
2/TR
Byte 58-59
Reserved
Optional
Byte 60-63
Manufacturer-specific diagnostics
Optional
7.2.2.1 Alarms
Bit
Meaning
= 0
= 1
E
xt
en
de
d
di
ag
nos
is
, by
te
8
Bit 0
Position error
No
Yes
Bit 1
Supply voltage faulty
No
Yes
Bit 2
Current consumption too high
No
Yes
Bit 3
Diagnosis
OK
Error
Bit 4
Memory error
No
Yes
Bit 5
Not applicable
Bit 6
Not applicable
Bit 7
Not applicable