Parameterization and configuration
Printed in the Federal Republic of Germany
TR-Electronic GmbH 2008, All Rights Reserved
06/19/2012
TR - ECE - BA - DGB - 0068 - 01
Page 79 of 109
Overview of operating parameters
see note on page 74
Bit coded operating parameters
DDLM_Set_Prm
Byte
9
Bit
7
– 0
Data
2
7
– 2
0
x = default setting
Bit Definition
= 0
= 1
Page
0
Count direction
ascending position values
for clockwise rotation
X
ascending position
values counter-
clockwise rotation
1
Class 2 Functionality
no
yes
X
2
Commissioning diagnostics
switched off
X
switched on
3
Scaling function
switched off
switched on
X
Associated operating parameters for scaling
Description see page 92
DDLM_Set_Prm
unsigned32
Byte
10
11
12
13
Bit
31
– 24
23
– 16
15
– 8
7
– 0
Data
2
31
– 2
24
2
23
– 2
16
2
15
– 2
8
2
7
– 2
0
Default (dec.)
4096
Steps per revolution
DDLM_Set_Prm
unsigned32
Byte
14
15
16
17
Bit
31
– 24
23
– 16
15
– 8
7
– 0
Data
2
31
– 2
24
2
23
– 2
16
2
15
– 2
8
2
7
– 2
0
Default (dec.)
16777216
Total measuring range