Parameterization and configuration
Printed in the Federal Republic of Germany
TR-Electronic GmbH 2008, All Rights Reserved
06/19/2012
TR - ECE - BA - DGB - 0068 - 01
Page 75 of 109
7.1 Overview
Configuration Operating parameters
*·
Length Features
PNO Class 1
Page 76
- Count direction
16 bit IN
- No measuring system scaling, the measuring
system has the base resolution according to the
nameplate
- 16 byte diagnosis data
- Count direction
PNO Class 1
Page 77
- Count direction
32 bit IN
PNO Class 2
Page 78
- Count direction
- Class 2 on/off
- Commissioning diagnostics
- Scaling function
- Steps per revolution
- Total measuring range
16 bit IN
16 bit OUT
- Measuring system scaling is possible, however
the number of steps / revolution must be an
integer and the number of revolutions an
exponent of 2
- Preset adjustment via the bus
- Count direction
PNO Class 2
Page 80
- Count direction
- Class 2 on/off
- Commissioning diagnostics
- Scaling function
- Steps per revolution
- Total measuring range
32 bit IN
32 bit OUT
TR-Mode
,
Position
Page 82
- Count direction
- Commissioning diagnostics
- Short Diagnostics
- Total measuring range
- Revolutions numerator
- Code PROFIBUS-Interface
- Preset
- Limit switch
32 bit IN
32 bit OUT
- Measuring system scaling is possible, however
the number of steps / revolution must be an
integer and the number of revolutions an
exponent of 2
- Preset adjustment via the bus
- Count direction
- Output code programming
- Preselection of the values for the external
Preset inputs
- Limit switch
TR-Mode
,
- Po
- Velocity
not supported!
–
–
*
from the bus master perspective