Parameterization and configuration
TR-Electronic GmbH 2008, All Rights Reserved
Printed in the Federal Republic of Germany
Page 90 of 109
TR - ECE - BA - DGB - 0068 - 01
06/19/2012
Assignment of the status byte
Bit Definition
25
Ready status
0
Measuring system not ready-to-operate
1
Measuring system ready-to-operate
26
Operating mode
0
Commissioning mode
1
Normal mode
27
Software limit switches
0
process-actual value lower limit switch or
process-actual value upper limit switch
1
process-actual value < lower limit switch or
process-actual value > upper limit switch
28
Counting direction
(at the moment)
0
Counting direction cw (with view on the shaft)
1
Counting direction ccw (with view on the shaft)
29
Teach-In,
takeover drive distance
0 not supported!
1 not supported!
30
Start Teach-In
0 not supported!
1 not supported!
31
Adjustment
acknowledgement
0
No adjustment requested
1
Requested adjustment was executed
Assignment of the control byte
Bit Definition
25
no meaning
26
no meaning
27
no meaning
28
Change counting direction
0 not supported!
1 not supported!
29
Takeover Teach-In
0 not supported!
1 not supported!
30
Start Teach-In
0 not supported!
1 not supported!
31
Adjustment request
0
No adjustment requested
1
Adjust measuring system to the preset value
Execution of the Preset adjustment
M = Master
Status-/Control bits
Data bits
S = Slave
Bit
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
M-->S
1
0
0
0
0
0
0
Here the preset value is transferred as desired new actual value
S-->M
0
0
0
0
0
0
0
The measuring system acknowledges the takeover in bit 7 of the status byte
M-->S
0
0
0
0
0
0
0
By setting the bit 31 to 0, the adjustment is finished
S-->M
0
0
0
0
0
0
0
The process actual value is now output again