27
compressor is heated without operation.
Preheating release condition:
If T4
>
5
℃
or the compressor starts running, the preheating function will stop.
8.3.8 Zero crossing detection error protection(except MSR1-24HRDN1-QRC4W)
If AC detects time interval is not correct for continuous 240s, the unit will stop and the LED will display
the failure. The correct zero crossing signal time interval should be between 6-13ms.
8.3.9 Sensor protection at open circuit and breaking disconnection.
When there’s one temperature sensor in malfunction, the air conditioner will display error code and will
not stop immediately, to avoid the case that the air conditioner is in urgent need.
Fault temp.
sensor
Operation in cooling, drying and
fan only mode
Operation in heating mode
T1
Run supposed T1=26
℃
high fan
speed
Run supposed T1=26
℃
high fan
speed
T2
Refer to table 1
Refer to table 2
T3
Run with compressor frequency
not higher than F14
3 minutes’ defrosting every 40
minutes when T4<7
℃
; 2 minutes’
defrosting every 90 minutes when
T4
≥
7
℃
.
T4
Run supposed T4=50
℃
Run
supposed
T4=15
℃
TP
Run supposed T4=50
℃
Run
supposed
T4=15
℃
T1
25
23
F12
F4(30 minutes on+3
minutes off)
table 1
T1
20
18
F4
F12(Indoor fan 1 minute
off, 1 minute M- ane then
the setting fan speed.)
table 2
8.4.10 Refrigerant leakage detection
This function is only active in cooling mode. It can better prevent the compressor being damaged
by refrigerant leakage or compressor overload.
Summary of Contents for TPG A128 IVP
Page 11: ...11 5 Wiring Diagram 5 1 Indoor Unit TPN A128 IVP TPN A135 IVP TPN A180 IVP TPN A240 IVP...
Page 12: ...12 5 2 Outdoor Unit TPGA128IVP TPG A135 IVP TPG A180 IVP...
Page 13: ...13 TPG A240 IVP...
Page 46: ...46 9 2 2 Indoor unit and outdoor unit communication protection error diagnosis and solution E1...
Page 50: ...50 9 2 7 Outdoor fan speed has been out of control diagnosis and solution F5...
Page 51: ...51 9 2 8 IPM malfunction or IGBT over strong current protection diagnosis and solution P0...
Page 52: ...52 9 2 9 Over voltage or too low voltage protection diagnosis and solution P1...
Page 53: ...53 9 2 10 Inverter compressor drive error diagnosis and solution P4...