SERVICE DATA
Starter assy
Current
Standard 90 A or less 11.5 V for 1.4 kW
100 A or less 11.5 V for 2.0 kW
Starter relay assy
Resistance
Standard 3 -- 5 10 k
Ω
or higher
Below 1
Ω
(Apply battery voltage to terminal 1 to 2)
Battery
Voltage
Standard 12.5 to 12.9 V at 20
_
C (68
_
F)
Charging circuit without load
Amperage
Standard
Voltage
Standard
10 A or less
13.2 to 14.8 V
Charging circuit with load
Amperage
Standard 30 A or less
Glow plug assy
Resistance
Standard Glow plug terminal -- Ground 0.6
Ω
at 20
_
C (68
_
F)
Glow plug relay assy
Resistance
Standard 1 -- 2 10 k
Ω
or higher
Below 1
Ω
(Apply battery voltage to terminal 3 to 4)