D27522
CORRECT INCORRECT
Z13951
NEVER USE AN OHMMETER ON AN AIRBAG OR PRETENSIONER
01 -- 12
--
INTRODUCTION
REPA IR INSTRUCTION
COROLLA Supplement (RM1129E)
(d) F RONT PASSENGER AIRBAG ASSEMBLY
(1) Always place a removed or new airbag assembly with the airbag inflation direction facing up.
Placing the airbag assembly with the airbag inflation direction facing down could cause a serious
accident if the airbag inflates.
(2) Never measure the resistance of the airbag squib. This may cause the airbag to inflate, which
could cause serious injury.
(3) Grease or detergents of any kind should not be applied to the airbag assembly.
(4) Store the airbag assembly in an area where the ambient temperature is below 93
˚
C (200
˚
F),
the humidity is not high and electrical noise is not nearby.
(5) When using electric welding anywhere on the vehicle, disconnect the airbag ECU connectors
(4 pins). These connectors contain shorting springs. This feature reduces the possibility of the
airbag deploying due to currents entering the squib wiring.
(6)
When disposing of a vehicle or the airbag assembly unit by itself, the airbag should be deployed
using SST before disposal
(see Pub. No. RM925E, page 60 -- 27).
Activate in a safe place away from electrical noise.
Example:
(e)
CURTAIN SHIELD AIRBAG ASSEMBLY
(1)
Always place the removed or new airbag assembly in a clear plastic bag, and keep it in a safe
place.
NOTICE:
The plastic bag is not reuseable.
CAUTION:
Never disassemble the curtain shield airbag assembly.
(2)
Never measure the resistance of the airbag squib. This may cause the airbag to inflate, which
could cause serious injury.
(3)
Grease or detergents of any kind should not be applied to the airbag assembly.
To Alphabetical Index