Configuring the EPW 400
OM 100.EPW 400.202002.en
91
Delete the curve data by tapping the 'Dustbin' button.
This button saves the recorded curves to a connected USB stick as a
CSV file. Depending on the size of the recorded curves, up to 100
curves are saved and copied on the USB stick. The name of the EPW
400 device as well as date and time will be used as name of the data
file. The data can be found on the USB stick in the "Tox\Archive" folder.
Close the 'Curve data' menu by tapping on 'Exit'.
6.3.2
Final values
To open this submenu, tap the 'Final values' button in the 'Data' menu:
After each measurement, a dataset of final values is stored. This dataset includes the
following information:
No.
Number of the measurement. 1000 final values are stored in a circu-
lar buffer, i.e. with each new measurement, the oldest dataset (= no.
999) is discarded and the newest is added (last measurement = no.
0)
Run. no.
Indicates a unique running number that increases by one after each
measurement
Prog.
Assignment of the measurement to a program
Status
State no. '2': Measurement OK (green background)
State no. '3': Measurement NOK (red background)
State no. – 4 = error number (see chapter 9 'Error messages')
Example: state no. '9': 9 – 4 = 5 => online window violated
Force
maximum force
Distance
Maximum distance
Date
Date of measurement (dd.mm.yy)
Time
Time of measurement (hh:mm:ss)
W1 F_in
Force entry in window 1
Summary of Contents for EPW400
Page 3: ......